• 产品与解决方案
  • 行业解决方案
  • 服务
  • 支持
  • 合作伙伴
  • 新华三人才研学中心
  • 关于我们

01-基础配置命令参考

目录

08-设备管理命令

本章节下载 08-设备管理命令  (427.60 KB)

08-设备管理命令

  录

1 设备管理

1.1 设备管理配置命令

1.1.1 clock datetime

1.1.2 clock protocol

1.1.3 clock summer-time

1.1.4 clock timezone

1.1.5 command

1.1.6 copyright-info enable

1.1.7 display alarm

1.1.8 display asset-info

1.1.9 display clock

1.1.10 display copyright

1.1.11 display cpu-usage

1.1.12 display cpu-usage configuration

1.1.13 display cpu-usage history

1.1.14 display device

1.1.15 display device manuinfo

1.1.16 display device manuinfo chassis-only

1.1.17 display device manuinfo fan

1.1.18 display device manuinfo power

1.1.19 display diagnostic-information

1.1.20 display environment

1.1.21 display fan

1.1.22 display memory

1.1.23 display memory-threshold

1.1.24 display power

1.1.25 display scheduler job

1.1.26 display scheduler logfile

1.1.27 display scheduler reboot

1.1.28 display scheduler schedule

1.1.29 display switch-mode status

1.1.30 display system-working-mode

1.1.31 display transceiver alarm

1.1.32 display transceiver diagnosis

1.1.33 display transceiver interface

1.1.34 display transceiver manuinfo

1.1.35 display version

1.1.36 display version-update-record

1.1.37 header

1.1.38 job

1.1.39 memory-threshold

1.1.40 monitor cpu-usage enable

1.1.41 monitor cpu-usage interval

1.1.42 monitor handshake-timeout disable-port

1.1.43 password-recovery enable

1.1.44 reboot

1.1.45 reset asset-info

1.1.46 reset version-update-record

1.1.47 reset scheduler logfile

1.1.48 scheduler job

1.1.49 scheduler logfile size

1.1.50 scheduler reboot at

1.1.51 scheduler reboot delay

1.1.52 scheduler schedule

1.1.53 set asset-info

1.1.54 shutdown-interval

1.1.55 switch-fabric isolate

1.1.56 switch-fabric removal-signal-suppression

1.1.57 switch-mode

1.1.58 sysname

1.1.59 system-working-mode

1.1.60 temperature-limit

1.1.61 time at

1.1.62 time once

1.1.63 time repeating

1.1.64 user-role


1 设备管理

1.1  设备管理配置命令

1.1.1  clock datetime

clock datetime命令用来设置设备的UTC(Coordinated Universal Time,国际协调时间)时间。

【命令】

clock datetime time date

【缺省情况】

设备的UTC时间为出厂时间。

【视图】

用户视图

【缺省用户角色】

network-admin

【参数】

time:设置的时间,格式为HH:MM:SS(小时:分钟:秒),HH取值范围为0~23,MM和SS取值范围为0~59。如果要设置成整分,则可以不输入秒;如果要设置成整点,则可以不输入分和秒。比如将time参数设置为0表示零点。

date:设置的日期,格式为MM/DD/YYYY(月/日/年)或者YYYY/MM/DD(年/月/日),MM的取值范围为1~12,DD的取值范围与月份有关,YYYY的取值范围为2000~2035。

【使用指导】

命令行配置的系统时间由配置的UTC时间、本地时区和夏令时运算之后联合决定,通过display clock命令可以查看。为了保证与其它设备协调工作,为了更好的监控和维护设备,请将系统时间配置准确。

【举例】

# 设置设备的UTC时间为2012年1月1日8时8分8秒。

<Sysname> clock datetime 8:8:8 1/1/2012

# 设置设备的UTC时间为2012年1月1日8时10分。

<Sysname> clock datetime 8:10 2012/1/1

【相关命令】

·     clock protocol

·     clock summer-time

·     clock timezone

·     display clock

1.1.2  clock protocol

clock protocol命令用来配置获取系统时间的方式。

undo clock protocol命令用来恢复缺省情况。

【命令】

clock protocol { none | ntp  mdc mdc-id }

undo clock protocol

【缺省情况】

由缺省MDC通过NTP协议获取系统时间。

【视图】

系统视图

【缺省用户角色】

network-admin

mdc-admin

【参数】

none:表示通过本地时钟源获取系统时间。配置该参数后,用户可通过clock datetimeclock timezoneclock summer-time命令修改系统时间。

ntp:表示通过NTP(Network Time Protocol,网络时间协议)协议获取系统时间。配置该参数后,用户不能通过命令行修改系统时间,需要配置NTP的相关参数才能获取到时钟。关于NTP的详细介绍和配置,请参见“网络管理和监控配置指导”中的“NTP”。

mdc mdc-id:表示时钟的来源MDC编号,取值范围为1~9。以编号为mdc-id的MDC的时钟信号作为整个设备的基准时钟。

【使用指导】

多次使用该命令配置不同的系统时间获取方式时,新配置将覆盖旧配置。

整个设备的系统时间只有一个,所有MDC共用一个时钟源。这个时钟源可以是设备上的本振,也可以是网络时钟源(来自其他网络设备)。

在配置本命令时,需要注意:

·     当时间协议为none时,表示使用本地时钟,用户可以使用命令行修改当前时间。设备上的本振会从新设置的时间开始计时。因为只有缺省MDC上有本振,所以该方式只有缺省MDC支持,本地时间只能在缺省MDC上配置。

·     当时间协议为NTP时,用户只能通过指定的MDC,并以NTP方式设置时间,其他方式都是不允许的。

【举例】

# 指定通过MDC 2内的NTP方式设置系统时间。

<Sysname> system-view

[Sysname] clock protocol ntp mdc 2

1.1.3  clock summer-time

clock summer-time命令用来设置夏令时。

undo clock summer-time命令用来恢复缺省情况。

【命令】

clock summer-time name start-time start-date end-time end-date add-time

undo clock summer-time

【缺省情况】

没有配置夏令时。

【视图】

系统视图

【缺省用户角色】

network-admin

mdc-admin

【参数】

name:夏令时的名称,为1~32个字符的字符串,区分大小写。

start-time:开始时间,格式为HH:MM:SS,HH取值范围为0~23,MM和SS取值范围为0~59。如果要设置成整分,则可以不输入秒;如果要设置成整点,则可以不输入分和秒。

start-date:开始日期,有两种输入方式:

·     直接一次性输入月和日,参数格式为MM/DD,MM取值范围为1~12,DD的取值范围与月份有关。

·     分次输入月、日,各参数之间以<空格>键隔开。首先输入开始的月份,取值如下:JanuaryFebruaryMarchAprilMayJuneJulyAugustSeptemberOctoberNovemberDecember;然后输入开始的星期,用当月的第几个星期表示,取值如下:firstsecondthirdfourthfifthlast;最后输入起始日,取值为SundayMondayTuesdayWednesdayThursdayFridaySaturday

end-time:结束时间,格式为HH:MM:SS,HH取值范围为0~23,MM和SS取值范围为0~59。如果要设置成整分,则可以不输入秒;如果要设置成整点,则可以不输入分和秒。

end-date:结束日期,有两种输入方式:

·     直接一次性输入月日,参数格式为MM/DD,MM取值范围为1~12,DD的取值范围与月份有关。

·     分次输入月、日,各参数之间以<空格>键隔开。首先输入开始的月份,取值如下:JanuaryFebruaryMarchAprilMayJuneJulyAugustSeptemberOctoberNovemberDecember;然后输入开始的星期,用当月的第几个星期表示,取值如下:firstsecondthirdfourthfifthlast;最后输入起始日,取值为SundayMondayTuesdayWednesdayThursdayFridaySaturday

add-time:偏移时间,格式为HH:MM:SS,HH取值范围为0~23,MM和SS取值范围为0~59。如果要设置成整分,则可以不输入秒;如果要设置成整点,则可以不输入分和秒。

【使用指导】

命令行配置的系统时间由配置的UTC时间、本地时区和夏令时运算之后联合决定,通过display clock命令可以查看。为了保证与其它设备协调工作,为了更好的监控和维护设备,请将所有网络设备的夏令时配置保持一致。

【举例】

# 设置夏令时PDT,从每年的8月1日的06:00:00开始,到9月1日的06:00:00结束,比当前设备标准时间增加1小时。

<Sysname> system-view

[Sysname] clock summer-time PDT 6 08/01 6 09/01 1

【相关命令】

·     display clock

·     clock protocol

·     clock timezone

1.1.4  clock timezone

clock timezone命令用来对本地时区进行设置。

undo clock timezone命令用来恢复缺省情况。

【命令】

clock timezone zone-name { add | minus } zone-offset

undo clock timezone

【缺省情况】

本地时区采用UTC时区。

【视图】

系统视图

【缺省用户角色】

network-admin

mdc-admin

【参数】

zone-name:时区名称,为1~32个字符的字符串,区分大小写。

add:在UTC时间的基础上增加指定时间。

minus:在UTC时间的基础上减少指定时间。

zone-offset:与UTC的时间差,格式为HH:MM:SS,HH取值范围为0~23,MM和SS取值范围为0~59,如果要设置成整分,则可以不输入秒;如果要设置成整点,则可以不输入分和秒。

【使用指导】

命令行配置的系统时间由配置的UTC时间、本地时区和夏令时运算之后联合决定,通过display clock命令可以查看。为了保证与其它设备协调工作,为了更好的监控和维护设备,请将所有网络设备的时区和当地地理时区保持一致。

【举例】

# 设置本地时区名称为Z5,比UTC标准时间增加5小时。

<Sysname> system-view

[Sysname] clock timezone Z5 add 5

【相关命令】

·     clock datetime

·     clock protocol

·     clock summer-time

·     display clock

1.1.5  command

command命令用来为Job分配命令。

undo command命令用来取消为Job分配的命令。

【命令】

command id command

undo command id

【缺省情况】

没有为Job分配命令。

【视图】

Job视图

【缺省用户角色】

network-admin

mdc-admin

【参数】

id:命令编号,取值范围为0~4294967295。该编号表示命令在Job中的执行顺序,编号小的命令优先执行。

command:为Job分配的命令。

【使用指导】

多次输入command命令可以为当前Job分配多条命令,不同命令用编号来唯一区别。如果新分配命令的编号和已分配的某命令的编号相同,则新分配的命令会覆盖已分配的命令。

需要注意的是,通过command指定的命令行必须是设备上可成功执行的命令行,不包括telnetftpssh2monitor process。由用户保证配置的正确性,否则,命令行不能自动被执行。

【举例】

# 为Job(假设名称为backupconfig)分配命令,以便将配置文件startup.cfg备份到TFTP服务器192.168.100.11。

<Sysname> system-view

[Sysname] scheduler job backupconfig

[Sysname-job-backupconfig] command 2 tftp 192.168.100.11 put flash:/startup.cfg backup.cfg

【相关命令】

·     scheduler job

1.1.6  copyright-info enable

copyright-info enable命令用来使能显示版权信息。

undo copyright-info enable命令用来禁止显示版权信息。

【命令】

copyright-info enable

undo copyright-info enable

【缺省情况】

显示版权信息处于开启状态。

【视图】

系统视图

【缺省用户角色】

network-admin

mdc-admin

【举例】

# 使能显示版权信息。

<Sysname> system-view

[Sysname] copyright-info enable

·     使用Telnet方式登录设备,会显示如下信息:

**************************************************************************

* Copyright (c) 2004-2014 Hangzhou H3C Tech. Co., Ltd. All rights reserved.*

* Without the owner's prior written consent,                               *

* no decompiling or reverse-engineering shall be allowed.                  *

****************************************************************************

 

<Sysname>

·     如果用户已通过Console口成功登录设备,再退出用户视图后,系统会自动尝试再次登录,此时会显示如下信息:

**************************************************************************

* Copyright (c) 2004-2014 Hangzhou H3C Tech. Co., Ltd. All rights reserved.*

* Without the owner's prior written consent,                               *

* no decompiling or reverse-engineering shall be allowed.                  *

****************************************************************************

 

User interface aux0 is available.

 

 

 

Press ENTER to get started.

# 禁止显示版权信息。

<Sysname> system-view

[Sysname] undo copyright-info enable

·     使用Telnet方式登录设备,会显示如下信息:

<Sysname>

·     如果用户已通过Console口成功登录设备,再退出用户视图后,系统会自动尝试再次登录,此时会显示如下信息:

User interface aux0 is available.

 

 

 

Press ENTER to get started.

1.1.7  display alarm

display alarm命令用来显示设备的告警信息。

【命令】

独立运行模式:

display alarm [ slot slot-number ]

IRF模式:

display alarm [ chassis chassis-number slot slot-number ]

【视图】

任意视图

【缺省级别】

network-admin

network-operator

mdc-admin

mdc-operator

【参数】

slot slot-number:显示指定单板的告警信息。slot-number表示单板所在的槽位号。不指定该参数时,则表示所有单板。(独立运行模式)

chassis chassis-number slot slot-number:显示指定单板或PEX设备上的告警信息。chassis-number表示设备在IRF中的成员编号或IRF3中PEX设备的虚拟框号,slot-number表示单板所在的槽位号。不指定该参数时,则显示所有单板的告警信息。(IRF模式)

【举例】

# 显示设备的告警信息。(独立运行模式)

<Sysname> display alarm

Slot   CPU   Level   Info                                              

-      -     ERROR   Fan 1 is faulty                         

-      -     INFO    Power 2 is absent.                      

-      -     INFO    Power 4 is absent.                      

-      -     INFO    Power 5 is absent.                      

-      -     INFO    Power 6 is absent.                      

-      -     INFO    Power 7 is absent.                      

-      -     INFO    Power 8 is absent. 

表1-1 display alarm命令显示信息描述表

字段

描述

Slot   CPU

产生告警的单板所在的槽位号及其CPU编号(如果显示为“-”,则表示产生告警的元件位于机框上)(独立运行模式)

Level

告警的级别,级别由高到低依次为ERROR、WARNING、NOTICE、INFO

Info

告警的详细信息

Fan n is.

风扇框n的状态:

·     absent:风扇框不在位

·     faulty:风扇框故障

Power n is.

电源n的状态:

·     absent:电源不在位

·     faulty:电源故障

Board is faulty

单板处于faulty状态(该单板可能正在启动,或者当前处于故障状态)

The temperature of sensor n exceeds the lower limit.

传感器n的温度低于低温门限

The temperature of sensor n exceeds the upper limit.

传感器n的温度高于高温门限

 

# 显示设备当前告警信息。(IRF模式)

<Sysname> display alarm

Chassis Slot   CPU   Level   Info                                              

1       -      -     ERROR   Chassis 1 fan 1 is faulty                         

1       -      -     INFO    Chassis 1 power 2 is absent.                      

1       -      -     INFO    Chassis 1 power 4 is absent.                      

1       -      -     INFO    Chassis 1 power 5 is absent.                      

1       -      -     INFO    Chassis 1 power 6 is absent.                      

1       -      -     INFO    Chassis 1 power 7 is absent.                      

1       -      -     INFO    Chassis 1 power 8 is absent. 

表1-2 display alarm命令显示信息描述表(IRF模式)

字段

描述

Chassis

告警设备的成员编号

Slot   CPU

告警单板所在的槽位号及其CPU编号

Level

告警的级别,级别由高到低依次为ERROR、WARNING、NOTICE、INFO

Info

告警的详细信息

Chassis x fan n is

成员设备x上风扇框n状态:

·     absent:风扇框不在位

·     faulty:风扇框故障

Chassis x power n is

成员设备x上电源n的状态:

·     absent:电源不在位

·     faulty:电源故障

 Board is faulty.

单板处于faulty状态(该单板可能正在启动,或者当前处于故障状态)

The temperature of sensor n exceeds the lower limit.

传感器n的温度低于低温门限

The temperature of sensor n exceeds the upper limit.

传感器n的温度高于高温门限

 

1.1.8  display asset-info

display asset-info命令用来显示设备的用户资产信息。使用该命令,可以显示设备机箱、单板、风扇框或电源模块的资产信息。

【命令】

独立运行模式:

display asset-info { chassis | fan fan-id | power power-id | slot slot-number } [ csn | custom| department | description | location | service-date | state ]

IRF模式:

display asset-info  chassis chassis-number { chassis | fan fan-id | power power-id | slot slot-number } [ csn | custom| department | description | location | service-date | state ]

【视图】

任意视图

【缺省用户角色】

network-admin

network-operator

mdc-admin

mdc-operator

【参数】

chassis:显示设备机箱的用户资产信息。

fan fan-id:显示指定风扇框的用户资产信息。fan-id表示设备上风扇框的编号。

power power-id:显示指定电源模块的用户资产信息。power-id表示设备上电源模块的编号。

slot slot-number:显示指定单板的用户资产信息。slot-number表示设备上单板所在的槽位号。

csn:显示资产编号信息。

custom:显示用户自定义的资产信息。

department:显示资产的归属部门信息。

description:显示资产的描述信息。

location:显示资产的位置信息。

service-date:显示资产的启用时间信息。

state:显示资产的使用状态信息。

chassis chassis-number:显示指定成员设备的用户资产信息。chassis-number表示设备在IRF中的成员编号。(IRF模式)

说明

显示指定电源模块的用户资产信息时,只支持csn参数。

 

【使用指导】

当用户希望显示设备机箱、单板或风扇框的具体信息项目(比如资产编号、资产描述信息等)时,只需要选择该信息项目对应的命令行参数;不选择具体信息项目对应的参数时,显示的是该设备机箱、单板或风扇框的所有用户资产信息。

使用该命令显示设备机箱、单板、风扇框或电源模块没有经过设置的具体信息项目时,该信息项目的内容显示为空。

使用该命令显示指定风扇框或者电源模块的资产信息时,如果设备上无对应编号的风扇框或者电源模块,将返回风扇框或者电源模块不在位的提示信息。

【举例】

# 显示设备上0号风扇框的资产编号信息(该显示信息与用户的当前配置有关)。(独立运行模式)

<Sysname> display asset-info fan 0 csn

Type        : Fan 0

csn         : 123456

# 显示设备上0号风扇框的资产信息(该显示信息与用户的当前配置有关)。(独立运行模式)

<Sysname> display asset-info fan 0

Type        : Fan 0

csn         : 123456

description : FAN 0

location    :

service-date:

department  : MKT

state       : Normal

custom:

# 显示1号成员设备上0号风扇框的资产编号信息(该显示信息与用户的当前配置有关)。(IRF模式)

<system-view> display asset-info chassis 1 fan 0 csn

Type        : Fan 0

csn         : 123456

# 显示1号成员设备上0号风扇框的资产信息(该显示信息与用户的当前配置有关)。(IRF模式)

<Sysname> display asset-info chassis 1 fan 0

Type        : Fan 0

csn         : 123456

description : FAN 0

location    :

service-date:

department  : MKT

state       : Normal

custom:

表1-3 display asset-info命令显示信息描述表

字段

描述

Type

资产类型,内容为指定的设备机箱、单板、风扇框或电源模块

csn

资产编号信息,内容为空表示用户没有进行设置

description

资产描述信息,内容为空表示用户没有进行设置

location

资产位置信息,内容为空表示用户没有进行设置

service-date

资产启用时间信息,内容为空表示用户没有进行设置

department

资产归属部门信息,内容为空表示用户没有进行设置

state

资产使用状态信息,内容为空表示用户没有进行设置

custom

用户自定义的资产信息,内容为空表示用户没有进行设置

 

【相关命令】

·     reset asset-info

·     set asset-info

1.1.9  display clock

display clock命令用来显示系统当前的时间、日期、本地时区以及夏令时配置。

【命令】

display clock

【视图】

任意视图

【缺省用户角色】

network-admin

network-operator

mdc-admin

mdc-operator

【举例】

# 没有配置本地时区时,显示系统当前日期和时间。

<Sysname> display clock

10:09:00 UTC Fri 03/16/2012

# 配置了本地时区Z5后,显示系统当前日期和时间。

<Sysname> display clock

15:10:00 Z5 Fri 03/16/2012

Time Zone : Z5 add 05:00:00

# 配置了本地时区Z5和夏令时PDT后,显示系统当前日期和时间。

<Sysname> display clock

15:11:00 Z5 Fri 03/16/2012

Time Zone : Z5 add 05:00:00

Summer Time : PDT 06:00:00 08/01 06:00:00 09/01 01:00:00

【相关命令】

·     clock datetime

·     clock timezone

·     clock summer-time

1.1.10  display copyright

display copyright命令用来显示系统软件和硬件的详细版权信息。

【命令】

display copyright

【视图】

任意视图

【缺省级别】

network-admin

network-operator

mdc-admin

mdc-operator

【使用指导】

通过查看版权信息,可以获知系统当前使用软件和硬件版本的版权信息、版权的参照标准、版权证书等相关信息。

【举例】

# 显示详细的软件版权信息。(本显示信息与设备的型号有关,请以设备的实际情况为准,此处略)

<Sysname> display copyright

1.1.11  display cpu-usage

display cpu-usage命令用来显示CPU利用率的统计信息。

【命令】

独立运行模式:

display cpu-usage [ slot slot-number [ cpu cpu-number ] ]

IRF模式:

display cpu-usage [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]

【视图】

任意视图

【缺省用户角色】

network-admin

network-operator

mdc-admin

mdc-operator

【参数】

slot slot-number:显示指定单板的CPU利用率的统计信息。slot-number表示单板所在的槽位号。不带该参数时,显示的是所有单板的相应信息。(独立运行模式)

chassis chassis-number slot slot-number:显示指定单板的CPU利用率的统计信息。chassis-number表示设备在IRF中的成员编号或PEX设备的虚拟框号,slot-number表示单板所在的槽位号。不指定该参数时,则显示所有单板及PEX设备上的CPU利用率统计信息。(IRF模式)

cpu cpu-number:显示指定CPU的利用率统计信息。cpu-number表示CPU的编号,取值只能为0。

【使用指导】

系统每隔一定的时间(通常为60秒)对CPU的利用率进行统计,并把统计结果保存到历史记录区。

【举例】

# 显示当前CPU利用率统计信息。(独立运行模式)

<Sysname> display cpu-usage

Slot 9 CPU 0 CPU usage:                                                        

       6% in last 5 seconds                                                    

       6% in last 1 minute                                                     

       6% in last 5 minutes                                                    

                                                                                

Slot 10 CPU 0 CPU usage:                                                       

       1% in last 5 seconds                                                    

       1% in last 1 minute                                                      

       2% in last 5 minutes                                                    

                                                                               

Slot 11 CPU 0 CPU usage:                                                        

       1% in last 5 seconds                                                    

       1% in last 1 minute                                                     

       1% in last 5 minutes                                                     

                                                                               

Slot 17 CPU 0 CPU usage:                                                       

       0% in last 5 seconds                                                     

       0% in last 1 minute                                                     

       0% in last 5 minutes

# 显示所有单板CPU利用率统计信息。(IRF模式)

<Sysname> display cpu-usage

Chassis 1 Slot 9 CPU 0 CPU usage:                                              

       5% in last 5 seconds                                                    

       5% in last 1 minute                                                     

       5% in last 5 minutes                                                    

                                                                                

Chassis 1 Slot 10 CPU 0 CPU usage:                                             

       1% in last 5 seconds                                                    

       1% in last 1 minute                                                     

       2% in last 5 minutes                                                    

                                                                               

Chassis 1 Slot 11 CPU 0 CPU usage:                                              

       1% in last 5 seconds                                                    

       1% in last 1 minute                                                     

       1% in last 5 minutes                                                     

                                                                               

Chassis 1 Slot 17 CPU 0 CPU usage:                                             

       4% in last 5 seconds                                                     

       2% in last 1 minute                                                     

       0% in last 5 minutes

表1-4 display cpu-usage命令显示信息描述表

字段

描述

1% in last 5 seconds

设备启动后,会以5秒为周期计算并记录一次该5秒内的CPU的平均利用率。该字段显示的是最近一个5秒统计周期内CPU的平均利用率

1% in last 1 minute

设备启动后,会以1分钟为周期计算并记录一次该1分钟内的CPU的平均利用率。该字段显示的是最近一个1分钟统计周期内CPU的平均利用率

1% in last 5 minutes

设备启动后,会以5分钟为周期计算并记录一次该5分钟内的CPU的平均利用率。该字段显示的是最近一个5分钟统计周期内CPU的平均利用率

Slot x CPU y CPU 0 usage

x号单板上y号CPU的CPU利用率信息(独立运行模式)

Chassis x Slot y CPU z CPU usage

x号成员设备y号单板上z号CPU的CPU利用率信息(IRF模式)

 

1.1.12  display cpu-usage configuration

display cpu-usage configuration命令用来显示CPU利用率历史信息记录功能相关配置。

【命令】

独立运行模式:

display cpu-usage configuration [ slot slot-number [ cpu cpu-number ] ]

IRF模式:

display cpu-usage configuration [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]

【视图】

任意视图

【缺省用户角色】

network-admin

mdc-admin

【参数】

slot slot-number:表示单板所在的槽位号。不指定该参数时,显示的是主用主控板上的相应信息。(独立运行模式)

cpu cpu-number:表示指定CPU。cpu-number表示CPU的编号,取值只能为0。

chassis chassis-number slot slot-number:显示指定单板或PEX设备上CPU利用率历史信息记录功能相关配置。chassis-number表示IRF中的成员设备编号或PEX设备的虚拟框号,slot-number表示单板所在的槽位号。不指定该参数时,则显示主用主控板上的相应信息。(IRF模式)

【举例】

# 查看当前主控板CPU使用率配置情况。

<Sysname> display cpu-usage configuration

CPU usage monitor is enabled.

Current monitor interval is 60 seconds.

Current monitor threshold is 99%.  

表1-5 display cpu-usage configuration命令显示信息描述表

字段

描述

CPU usage monitor is enabled.

CPU利用率历史记录功能已开启。

Current monitor interval is 60 seconds.

当前CPU利用率历史记录的采样周期为60秒。

Current monitor threshold is 99%.

当前CPU利用率阈值为99%

 

1.1.13  display cpu-usage history

display cpu-usage history命令用来以图表方式显示CPU利用率历史信息。

【命令】

独立运行模式:

display cpu-usage history [ job job-id ] [ slot slot-number [ cpu cpu-number ] ]

IRF模式:

display cpu-usage history [ job job-id ] [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]

【视图】

任意视图

【缺省用户角色】

network-admin

network-operator

mdc-admin

mdc-operator

【参数】

job job-id:显示指定进程的CPU利用率的历史信息,job-id表示进程的编号。不使用该参数时,显示的是整个系统的相应信息(整个系统的CPU利用率等于所有进程CPU利用率之和)。可以使用display process命令可以查看当前运行的进程的编号和名称,display process命令的详细介绍请参见“网络管理与监控”中的“系统维护与调试”。

slot slot-number:显示指定单板的CPU利用率的历史信息。slot-number表示单板所在的槽位号。不带该参数时,显示的是主用主控板的相应信息。(独立运行模式)

chassis chassis-number slot slot-number:显示指定单板或PEX设备CPU利用率的历史信息。chassis-number表示设备在IRF中的成员编号或IRF3中PEX设备的虚拟框号,slot-number表示单板所在的槽位号。不指定该参数时,显示所有单板及PEX设备CPU利用率低历史信息。(IRF模式)

cpu cpu-number:显示指定CPU的利用率的历史信息。cpu-number表示CPU的编号,取值只能为0。

【使用指导】

系统每隔一定时间会对CPU的利用率进行统计,并把统计结果保存到历史记录区。通过display cpu-usage history命令可以查看到最近60分钟记录的CPU利用率统计值。结果以坐标的形式进行显示,显示信息中:

·     纵坐标表示利用率,采用就近显示的原则。比如,利用率的间隔为5%,则实际统计值53%将被显示成55%,实际统计值52%将被显示成50%。

·     横坐标表示时间,时间越靠左表示距离当前时间越近。

·     用连续的#号表示该时刻的利用率,某个时间点上最高处的#号对应的纵坐标值即为该时刻CPU的利用率。

【举例】

# 以图表方式显示整个系统的CPU利用率历史信息。(独立运行模式)

<Sysname> display cpu-usage history

100%|

 95%|

 90%|

 85%|

 80%|

 75%|

 70%|

 65%|

 60%|

 55%|

 50%|

 45%|

 40%|

 35%|

 30%|

 25%|

 20%|

 15%|             #

 10%|            ###  #

  5%|           ########

     ------------------------------------------------------------

              10        20        30        40        50        60  (minutes)

                      cpu-usage (slot 1 CPU 0) last 60 minutes (SYSTEM)

---- More ----   

以上显示信息表明整个系统(用“SYSTEM”表示)在最近60分钟内CPU的利用率情况:

·     12分钟前大约为5%;

·     13分钟前大约为10%;

·     14分钟前大约为15%;

·     15分钟前大约为10%;

·     16、17分钟前大约为5%;

·     18分钟前大约为10%;

·     19分钟前大约为5%;

·     其它时间均小于或等于2%。

# 以图表方式显示编号为1的进程的CPU利用率历史信息。(独立运行模式)

<Sysname> display cpu-usage history job 1

100%|

 95%|

 90%|

 85%|

 80%|

 75%|

 70%|

 65%|

 60%|

 55%|

 50%|

 45%|

 40%|

 35%|

 30%|

 25%|

 20%|

 15%|

 10%|

  5%|                   #

     ------------------------------------------------------------

              10        20        30        40        50        60  (minutes)

                      cpu-usage (slot 17 CPU 0) last 60 minutes (scmd)

---- More ----

以上显示信息表明编号为1的进程(进程名为scmd,如果进程名带有“[]”标识则表示它是内核线程)在最近60分钟内CPU的利用率情况:20分钟前大约为5%,其它时间均小于或等于2%。

1.1.14  display device

display device命令用来显示设备信息。

【命令】

独立运行模式:

display device [ flash ] [ slot slot-number [ subslot subslot-number ] | verbose ]

IRF模式:

display device [ flash ] [ chassis chassis-number [ slot slot-number [ subslot subslot-number ] ] | verbose ]

【视图】

任意视图

【缺省用户角色】

network-admin

network-operator

mdc-admin

mdc-operator

【参数】

flash:显示FLASH的信息。

slot slot-number:显示指定单板的信息。slot-number表示单板所在的槽位号。(独立运行模式)

chassis chassis-number:显示指定成员设备或PEX设备的详细信息。chassis-number表示设备在IRF中的成员编号或IRF3中PEX设备的虚拟框号。不指定该参数时,显示所有成员设备及PEX设备的设备信息。(IRF模式)

slot slot-number:显示指定单板或PEX设备的电子标签信息。(IRF模式)

·     当chassis-number指定为成员设备编号时,slot-number表示单板所在的槽位号。不输入该参数时,显示所有单板的电子标签信息。

·     当chassis-number指定为PEX设备虚拟框号时,slot-number取值只能为0。

subslot subslot-number:显示指定子卡的信息。subslot-number表示子卡所在的子槽位号。当本系列交换机在IRF3环境下,且PEX设备型号为S5500-HI/S5120-HI时才支持子卡。

verbose:显示设备的详细信息。不指定该参数时,显示设备的简要信息。

【使用指导】

不带flash参数时,显示的是设备上所有单板的信息。

【举例】

# 显示设备信息。(独立运行模式)

<Sysname> display device

Slot No. Brd Type         Brd State    Subslot Sft Ver                 Patch Ver

 0       LSX1TGS48FB0     Normal       0       S12500-F-1030L16        None     

 1       LSX1TGS48FB0     Normal       0       S12500-F-1030L16        None     

 2       LSX1TGS48FB0     Normal       0       S12500-F-1030L16        None     

 3       LSX1TGS48FB0     Normal       0       S12500-F-1030L16        None     

 4       LSX1TGS48FB0     Normal       0       S12500-F-1030L16        None     

 5       LSX1QGS12EC0     Normal       0       S12500-F-1030L16        None     

 6       LSX1QGS12EC0     Normal       0       S12500-F-1030L16        None     

 7       LSX1QGS12EC0     Normal       0       S12500-F-1030L16        None     

 8       LSX1QGS12EC0     Normal       0       S12500-F-1030L16        None     

 9       LSX1QGS12EC0     Normal       0       S12500-F-1030L16        None     

 10      LSX1FAB10A0      Normal       0       S12500-F-1030L16        None     

 11      LSX1FAB10A0      Normal       0       S12500-F-1030L16        None     

 12      LSX1FAB10A0      Normal       0       S12500-F-1030L16        None     

 13      LSX1FAB10A0      Normal       0       S12500-F-1030L16        None     

 14      LSX1FAB10A0      Normal       0       S12500-F-1030L16        None     

 15      LSX1FAB10A0      Normal       0       S12500-F-1030L16        None     

 16      LSX1SUP10A0      Standby      0       S12500-F-1030L16        None

 17      LSX1SUP10A0      Master       0       S12500-F-1030L16        None

以上显示信息表明,独立运行模式时,设备上有10块业务板(位于0~9号槽位),6块网板(位于10~15号槽位),两块主控板(位于16、17号槽位)。

表1-6 display device命令显示信息描述表(独立运行模式)

字段

描述

Slot No.

单板的槽位号

Brd Type

单板的硬件类型

Brd Status

单板状态:

·     Standby表示该板是备用主控板

·     Master表示该板是主用主控板

·     Absent表示该槽位没有插入单板

·     Fault表示该槽位单板出错,不能正常启动

·     Normal表示该槽位单板处于正常工作状态

Subslot

单板支持子卡的最大个数

Sft Ver

当前单板上运行的软件版本

Patch Ver

当前单板上运行的热补丁版本

 

# 显示IRF中各成员设备的设备信息。(IRF模式)

<Sysname> display device

Slot   Type             State       Subslot  Soft Ver              Patch Ver

1/0    LSX1TGS48FB0     Normal       0       S12500-F-1030L16      None

1/1    LSX1TGS48FB0     Normal       0       S12500-F-1030L16      None

1/2    LSX1TGS48FB0     Normal       0       S12500-F-1030L16      None

1/3    LSX1TGS48FB0     Normal       0       S12500-F-1030L16      None

1/4    LSX1TGS48FB0     Normal       0       S12500-F-1030L16      None

1/5    LSX1TGS48FB0     Normal       0       S12500-F-1030L16      None

1/6    LSX1TGS48FB0     Normal       0       S12500-F-1030L16      None

1/7    LSX1TGS48FB0     Normal       0       S12500-F-1030L16      None

1/8    LSX1TGS48FB0     Normal       0       S12500-F-1030L16      None

1/9    LSX1TGS48FB0     Normal       0       S12500-F-1030L16      None    

1/10   LSX1FAB10A0      Normal       0       S12500-F-1030L16      None    

1/11   LSX1FAB10A0      Normal       0       S12500-F-1030L16      None    

1/12   LSX1FAB10A0      Normal       0       S12500-F-1030L16      None

1/13   LSX1FAB10A0      Normal       0       S12500-F-1030L16      None

1/14   LSX1FAB10A0      Normal       0       S12500-F-1030L16      None

1/15   LSX1FAB10A0      Normal       0       S12500-F-1030L16      None

1/16   LSX1SUP10A0      Standby      0       S12500-F-1030L16      None

1/17   LSX1SUP10A0      Master       0       S12500-F-1030L16      None

2/0    LSX1TGS48FB0     Normal       0       S12500-F-1030L16      None

2/1    LSX1TGS48FB0     Normal       0       S12500-F-1030L16      None

2/2    LSX1TGS48FB0     Normal       0       S12500-F-1030L16      None

2/3    LSX1TGS48FB0     Normal       0       S12500-F-1030L16      None

2/4    LSX1TGS48FB0     Normal       0       S12500-F-1030L16      None

2/5    LSX1TGS48FB0     Normal       0       S12500-F-1030L16      None

2/6    LSX1TGS48FB0     Normal       0       S12500-F-1030L16      None

2/7    LSX1TGS48FB0     Normal       0       S12500-F-1030L16      None

2/8    LSX1TGS48FB0     Normal       0       S12500-F-1030L16      None

2/9    LSX1TGS48FB0     Normal       0       S12500-F-1030L16      None    

2/10   LSX1FAB10A0      Normal       0       S12500-F-1030L16      None    

2/11   LSX1FAB10A0      Normal       0       S12500-F-1030L16      None    

2/12   LSX1FAB10A0      Normal       0       S12500-F-1030L16      None

2/13   LSX1FAB10A0      Normal       0       S12500-F-1030L16      None

2/14   LSX1FAB10A0      Normal       0       S12500-F-1030L16      None

2/15   LSX1FAB10A0      Normal       0       S12500-F-1030L16      None

2/16   LSX1SUP10A0      Standby      0       S12500-F-1030L16      None

2/17   LSX1SUP10A0      Standby      0       S12500-F-1030L16      None

以上显示信息表明,该IRF中包含两台成员设备,编号分别为12。同时还显示了每个框上的单板信息。从单板状态可以看出,成员设备1的17号单板为整个IRF的主用主控板,16号单板为备用主控板;成员设备2的16、17号单板均为整个IRF的备用主控板。

表1-7 display device命令显示信息描述表(IRF模式)

字段

描述

Slot

设备在IRF中的成员编号

Type

单板型号

State

单板的当前状态:

·     Absent:单板不在位

·     Master:单板为全局主用主控板(即整个IRF的主用主控板)

·     Standby:单板为全局备用主控板(即整个IRF的备用主控板)

·     Normal:单板状态正常

·     Fault:单板状态异常

Subslot

单板支持子卡的最大个数。目前,本系列交换机不支持子卡。

Soft Ver

当前单板上运行的软件版本

Patch Ver

当前单板上运行的热补丁版本,None表示没有补丁

 

1.1.15  display device manuinfo

display device manuinfo命令用来显示设备的电子标签信息。

【命令】

独立运行模式:

display device manuinfo [ slot slot-number ]

IRF模式:

display device manuinfo [ chassis chassis-number [ slot slot-number ] ]

【视图】

任意视图

【缺省用户角色】

network-admin

network-operator

mdc-admin

mdc-operator

【参数】

slot slot-number:显示指定单板的电子标签信息。slot-number表示单板所在的槽位号。不输入该参数时,显示所有单板的电子标签信息。(独立运行模式)

chassis chassis-number:显示指定成员设备或PEX设备的电子标签信息。chassis-number表示设备在IRF中的成员编号或IRF3中PEX设备的虚拟框号。不指定该参数,显示所有成员设备及PEX设备的电子标签信息。(IRF模式)

slot slot-number:显示指定单板或PEX设备的电子标签信息。(IRF模式)

·     当chassis-number指定为成员设备编号时,slot-number表示单板所在的槽位号。不输入该参数时,显示所有单板的电子标签信息。

·     当chassis-number指定为PEX设备虚拟框号时,slot-number取值只能为0。

【使用指导】

电子标签信息也可以称为永久配置数据或档案信息等,在单板或者设备的调测(调试、测试)过程中被写入到设备的存储器件中,包括单板的名称、生产序列号、MAC地址、制造商等信息。本命令显示的是设备的部分电子标签信息。

【举例】

# 显示设备的电子标签信息。(独立运行模式)

<Sysname> display device manuinfo

Chassis self

DEVICE_NAME          : S12510-F

DEVICE_SERIAL_NUMBER : 02A0WU0128000055

MAC_ADDRESS          : 0004-7679-C101

MANUFACTURING_DATE   : 2013-05-06

VENDOR_NAME          : H3C

 Slot 1 CPU 0:

DEVICE_NAME          : LSX1TGS48FB0

DEVICE_SERIAL_NUMBER : 210231A73SA07B000075

MAC_ADDRESS          : 000F-E26A-581B

MANUFACTURING_DATE   : 2012-11-10

VENDOR_NAME          : H3C

 Slot 2 CPU 0:

DEVICE_NAME          : LSX1TGS48FB0

DEVICE_SERIAL_NUMBER : 210231A76VX081000020

MAC_ADDRESS          : 000F-0123-4565

MANUFACTURING_DATE   : 2012-12-2

VENDOR_NAME          : H3C

 Slot 10 CPU 0:

DEVICE_NAME          : LSX1FAB10A0

DEVICE_SERIAL_NUMBER : 210231A76VX081000020

MAC_ADDRESS          : 1231-2312-3123

MANUFACTURING_DATE   : 2012-12-2

VENDOR_NAME          : H3C

 Slot 16 CPU 0:

DEVICE_NAME          : LSX1SUP10A0

DEVICE_SERIAL_NUMBER : 210231S12598XSUP1002

MAC_ADDRESS          : 000F-0123-4565

MANUFACTURING_DATE   : 2012-12-2

VENDOR_NAME          : H3C

Fan 2

DEVICE_NAME          : LSXE110FAN
DEVICE_SERIAL_NUMBER : 210231S1265047679F02

MAC_ADDRESS          : 0004-7679-0A20

MANUFACTURING_DATE   : 2013-05-06

VENDOR_NAME          : H3C

Power 1

DEVICE_NAME          : LSTM2PSRA

DEVICE_SERIAL_NUMBER : 210231A0HHN128000169

MAC_ADDRESS          : 0000-FE91-3456

MANUFACTURING_DATE   : 2012-08-14

VENDOR_NAME          : H3C

Power 3

DEVICE_NAME          : LSTM2PSRA

DEVICE_SERIAL_NUMBER : LBLNPW12CS15009116

MAC_ADDRESS          : 0000-FE91-3456

MANUFACTURING_DATE   : 2012-08-14

VENDOR_NAME          : H3C

Power 5

DEVICE_NAME          : LSTM2PSRA

DEVICE_SERIAL_NUMBER : LBLNPW12CS25012311

MAC_ADDRESS          : 0000-FE91-3456

MANUFACTURING_DATE   : 2012-08-14

VENDOR_NAME          : H3C

# 显示设备的电子标签信息。(IRF模式)

<Sysname> display device manuinfo

Chassis 1:

Chassis self

DEVICE_NAME          : S12510-F

DEVICE_SERIAL_NUMBER : 02A0WU0128000055

MAC_ADDRESS          : 0004-7679-C101

MANUFACTURING_DATE   : 2013-05-06

VENDOR_NAME          : H3C

 Slot 1 CPU 0:

DEVICE_NAME          : LSX1TGS48FB0

DEVICE_SERIAL_NUMBER : 210231A73SA07B000075

MAC_ADDRESS          : 000F-E26A-581B

MANUFACTURING_DATE   : 2012-11-10

VENDOR_NAME          : H3C

 Slot 10 CPU 0:

DEVICE_NAME          : LSX1FAB10A0

DEVICE_SERIAL_NUMBER : 210231A76VX081000020

MAC_ADDRESS          : 1231-2312-3123

MANUFACTURING_DATE   : 2012-12-2

VENDOR_NAME          : H3C

 Slot 16 CPU 0:

DEVICE_NAME          : LSX1SUP10A0

DEVICE_SERIAL_NUMBER : 210231S125096SUP1002

MAC_ADDRESS          : 000F-0123-4565

MANUFACTURING_DATE   : 2012-12-2

VENDOR_NAME          : H3C

Fan 2

DEVICE_NAME          : LSXE110FAN
DEVICE_SERIAL_NUMBER : 210231S1201047679F02

MAC_ADDRESS          : 0004-7679-0A20

MANUFACTURING_DATE   : 2013-05-06

VENDOR_NAME          : H3C

Power 1

DEVICE_NAME          : LSTM2PSRA

DEVICE_SERIAL_NUMBER : 210231A0HHN128000169

MAC_ADDRESS          : 0000-FE91-3456

MANUFACTURING_DATE   : 2012-08-14

VENDOR_NAME          : H3C

Power 3

DEVICE_NAME          : LSTM2PSRA

DEVICE_SERIAL_NUMBER : LBLNPW12CS15009116

MAC_ADDRESS          : 0000-FE91-3456

MANUFACTURING_DATE   : 2012-08-14

VENDOR_NAME          : H3C

Power 5

DEVICE_NAME          : LSTM2PSRA

DEVICE_SERIAL_NUMBER : LBLNPW12CS25012311

MAC_ADDRESS          : 0000-FE91-3456

MANUFACTURING_DATE   : 2012-08-14

VENDOR_NAME          : H3C

表1-8 display device manuinfo命令信息显示描述表

字段

描述

Chassis 1

成员设备编号(IRF模式)

Chassis self

整个机箱

Slot 1 CPU 0

单板所在槽位号和CPU编号

DEVICE_NAME

设备名称

DEVICE_SERIAL_NUMBER

设备序列号

MAC_ADDRESS

设备出厂MAC地址

MANUFACTURING_DATE

设备调测日期

VENDOR_NAME

制造商名称

 

1.1.16  display device manuinfo chassis-only

display device manuinfo chassis-only命令用来显示指定机框背板的电子标签信息。

【命令】

独立运行模式:

display device manuinfo chassis-only

IRF模式:

display device manuinfo chassis chassis-number chassis-only

【视图】

任意视图

【缺省用户角色】

network-admin

network-operator

mdc-admin

mdc-operator

【参数】

chassis chassis-number:表示设备在IRF中的成员编号。(IRF模式)

【举例】

# 显示机框背板的电子标签信息。(独立运行模式)

<Sysname> display device manuinfo chassis-only

Chassis self

 DEVICE_NAME          : S12510-F

 DEVICE_SERIAL_NUMBER : 02A0WU0128000055

 MAC_ADDRESS          : 0004-7679-C101

 MANUFACTURING_DATE   : 2013-05-06

 VENDOR_NAME          : H3C

# 显示成员设备1上机框背板的电子标签信息。(IRF模式)

<Sysname> display device manuinfo chassis 1 chassis-only

Chassis 1

Chassis self:

 DEVICE_NAME            : S12510-F

 DEVICE_SERIAL_NUMBER   : 02A0WU0127000002

 MAC_ADDRESS            : 0000-FE01-3456

 MANUFACTURING_DATE     : 2012-12-28

 VENDOR_NAME            : H3C

1.1.17  display device manuinfo fan

display device manuinfo fan命令用来显示指定风扇的电子标签信息。

【命令】

独立运行模式:

display device manuinfo fan fan-id

IRF模式:

display device manuinfo chassis { actual-chassis-number | virtual-chassis-number slot slot-number } fan fan-id

【视图】

任意视图

【缺省用户角色】

network-admin

network-operator

mdc-admin

mdc-operator

【参数】

chassis actual-chassis-number:显示指定成员设备上风扇的电子标签信息。actual-chassis-number表示设备在IRF中的成员编号。

chassis virtual-chassis-number slot slot-number:显示指定PEX设备上风扇的电子标签信息。Virtual-chassis-number表示PEX设备的虚拟框号,slot-number取值只能为0。

fan-id:表示设备上风扇的ID编号。

【举例】

# 显示风扇1的电子标签信息。(独立运行模式)

<Sysname> display device manuinfo fan 1

Fan 1:

DEVICE_NAME          : LSXE110FAN

DEVICE_SERIAL_NUMBER : 210231S125X047679F02

MAC_ADDRESS          : 0004-7679-0A20

MANUFACTURING_DATE   : 2013-05-06

VENDOR_NAME          : H3C

# 显示成员设备1上风扇1的电子标签信息。(IRF模式)

<Sysname> display device manuinfo chassis 1 fan 1

Chassis 1:

Fan 1:

 DEVICE_NAME          : LSXE110FAN

 DEVICE_SERIAL_NUMBER : 210231S125X047679F02

 MAC_ADDRESS          : 0004-7679-0A20

 MANUFACTURING_DATE   : 2013-05-06

 VENDOR_NAME          : H3C

1.1.18  display device manuinfo power

display device manuinfo power命令用来显示指定电源的电子标签信息。

【命令】

独立运行模式:

display device manuinfo power power-id

IRF模式:

display device manuinfo chassis { actual-chassis-number | virtual-chassis-number slot slot-number } power power-id

【视图】

任意视图

【缺省用户角色】

network-admin

network-operator

mdc-admin

mdc-operator

【参数】

chassis actual-chassis-number:显示指定成员设备上电源的电子标签信息。actual-chassis-number表示设备在IRF中的成员编号。

chassis virtual-chassis-number slot slot-number:显示指定PEX设备上电源的电子标签信息。Virtual-chassis-number表示PEX设备的虚拟框号,slot-number取值只能为0。

power-id:表示设备上电源的ID编号。

【举例】

# 显示电源1的电子标签信息。(独立运行模式)

<Sysname> display device manuinfo power 1

Power 1:

DEVICE_NAME          : LSTM2PSRA

DEVICE_SERIAL_NUMBER : 210231A0HHN128000169

MANUFACTURING_DATE   : 2012-08-14

VENDOR_NAME          : H3C

# 显示成员设备1上电源1的电子标签信息。(IRF模式)

<Sysname> display device manuinfo chassis 1 power 1

Chassis 1:

Power 1:

 DEVICE_NAME            : LSTM2PSRA

 DEVICE_SERIAL_NUMBER   : 210231A0HHN128000008

 MANUFACTURING_DATE     : 2012-08-11

 VENDOR_NAME            : H3C

1.1.19  display diagnostic-information

display diagnostic-information命令用来显示系统当前多个功能模块运行的统计信息。

【命令】

display diagnostic-information [ hardware | infrastructure | l2 | l3 | service ] [ filename ]

【视图】

任意视图

【缺省用户角色】

network-admin

network-operator

mdc-admin

mdc-operator

【参数】

hardware:收集硬件相关诊断信息。

infrastructure:收集基础模块的诊断信息。

l2:收集二层特性相关诊断信息。

l3:收集三层特性相关诊断信息。

service:收集上层业务模块相关诊断信息。

filename:表示将收集到的诊断信息保存到指定文件。filename表示文件的名称,后缀必须为“.tar.gz”。

【使用指导】

在日常维护或系统出现故障时,为了便于问题定位,用户需要查看各个功能模块的运行信息。因为各个功能模块都有其对应的运行信息,所以一般情况下,用户需要逐条运行相应的display命令。为便于一次性收集更多信息,用户可以在任意视图下执行display diagnostic-information命令,显示系统当前多个功能模块运行的统计信息。

该命令不支持“|”、“>”和“>>”参数,执行该命令后,用户可以选择直接显示指定的诊断信息或者将诊断信息直接保存到指定文件,因为诊断信息较多,系统会自动将该文件压缩后保存。

【举例】

# 显示系统当前各个功能模块运行的统计信息(因为显示信息多,而且跟设备型号有关,请以设备的实际情况为准,此处略)。

<Sysname> display diagnostic-information

Save or display diagnostic information (Y=save, N=display)? [Y/N]:n

===============================================

  ===============display clock===============

14:03:55 UTC Thu 01/05/2013

=================================================

  ===============display version=============== 

……略……

1.1.20  display environment

display environment命令用来显示设备上温度传感器的温度信息,包括当前温度和设定的温度告警门限。

【命令】

独立运行模式:

display environment [ slot slot-number ]

IRF模式:

display environment [ chassis chassis-number [ slot slot-number ] ]

【视图】

任意视图

【缺省用户角色】

network-admin

network-operator

mdc-admin

mdc-operator

【参数】

slot slot-number:显示设备中指定单板上的温度传感器的温度信息。slot-number表示单板所在的槽位号。不指定该参数时,显示的是设备上所有温度传感器的温度信息。(独立运行模式)

chassis chassis-number:显示指定成员设备或PEX设备上温度传感器的温度信息。chassis-number表示设备在IRF中的成员编号或PEX设备的虚拟框号。不指定该参数时,显示所有成员设备及PEX设备上温度传感器的温度信息。(IRF模式)

slot slot-number:显示指定单板或PEX设备的温度传感器的温度信息。(IRF模式)

·     当chassis-number指定为成员设备编号时,slot-number表示单板所在的槽位号。不输入该参数时,显示所有单板的电子标签信息。

·     当chassis-number指定为PEX设备虚拟框号时,slot-number取值只能为0。

【举例】

# 显示设备上所有温度传感器的温度信息。(独立运行模式)

<Sysname> display environment

System temperature information (degree centigrade):                           

 ----------------------------------------------------------------------        

 Slot  Sensor    Temperature  Lower  Warning  Alarm  Shutdown                  

 9     hotspot 1 42           0      80       95     100                       

 9     hotspot 2 39           0      80       95     100                       

 9     hotspot 3 41           0      80       95     100                       

 9     hotspot 4 38           0      80       95     100                       

 10    hotspot 1 42           0      75       90     95                        

 10    hotspot 2 34           0      75       90     95                        

 10    hotspot 3 37           0      75       90     95                        

 11    hotspot 1 45           0      75       90     95                        

 11    hotspot 2 35           0      75       90     95                        

 11    hotspot 3 39           0      75       90     95                        

 17    inflow  1 37           0      57       72     77                        

 17    hotspot 1 40           0      76       88     93                        

 17    hotspot 2 37           0      76       88     93

# 显示IRF中所有温度传感器的温度信息。(IRF模式)

<Sysname> display environment

System temperature information (degree centigrade):                           

 ----------------------------------------------------------------------        

 Chassis  Slot  Sensor    Temperature  Lower  Warning  Alarm  Shutdown          

 1        9     hotspot 1 50           0      80       95     100              

 1        9     hotspot 2 48           0      80       95     100              

 1        9     hotspot 3 50           0      80       95     100              

 1        9     hotspot 4 47           0      80       95     100              

 1        10    hotspot 1 50           0      75       90     95               

 1        10    hotspot 2 44           0      75       90     95               

 1        10    hotspot 3 47           0      75       90     95               

 1        11    hotspot 1 52           0      75       90     95               

 1        11    hotspot 2 45           0      75       90     95               

 1        11    hotspot 3 49           0      75       90     95               

 1        17    inflow  1 47           0      57       72     77               

 1        17    hotspot 1 49           0      76       88     93               

 1        17    hotspot 2 47           0      76       88     93

表1-9 display environment命令显示信息描述表

字段

描述

System temperature information (degree centigrade)

系统温度信息(单位为摄氏度)

Sensor

温度传感器

·     hotspot:表示热点温度传感器

·     inflow:表示入风口温度传感器

Slot

指定槽位单板上温度传感器的温度信息(独立运行模式)

Chassis     Slot

指定成员设备指定单板上温度传感器的温度信息( IRF模式)

Temperature

当前温度

Lower

低温告警门限

Warning

一般级(Warning)高温告警门限

Alarm

严重级(Alarm)高温告警门限

Shutdown

关断级(Shutdown)高温告警门限,当温度传感器的温度大于该门限时,设备会自动关闭

 

1.1.21  display fan

display fan命令用来显示设备风扇的工作状态。

【命令】

独立运行模式:

display fan [ fan-id ]

IRF模式:

display fan [ chassis { actual-chassis-number | virtual-chassis-number slot slot-number } [ fan-id ] ]

【视图】

任意视图

【缺省用户角色】

network-admin

network-operator

mdc-admin

mdc-operator

【参数】

chassis actual-chassis-number:显示指定成员设备上风扇的状态信息。actual-chassis-number表示设备在IRF中的成员编号。

chassis virtual-chassis-number slot slot-number:显示指定PEX设备上风扇的状态信息。virtual-chassis-number表示PEX设备的虚拟框号,slot-number取值只能为0。

fan-id:显示指定风扇的状态信息。fan-id表示设备内置风扇的编号。

【使用指导】

不指定成员设备和PEX设备时,显示所有成员设备及PEX设备上的风扇状态信息。

【举例】

# 显示设备上所有风扇的工作状态。(独立运行模式)

<Sysname> display fan

Fan-tray 1:                                                                   

 Status    : Absent                                                            

 Fan-tray 2:                                                                   

 Status    : Normal                                                            

 Fan number: 5                                                                 

 Fan mode  : Auto                                                              

 Airflow Direction: Front-to-back                                              

 Fan  Status      Speed(rpm)                                                   

 ---  ----------  ----------                                                   

  1   Normal      3483                                                         

  2   Normal      1687                                                          

  3   Normal      2557                                                         

  4   Normal      1651                                                         

  5   Normal      2539

# 显示设备上所有风扇的工作状态。(IRF模式)

<Sysname> display fan

Chassis 1:                                                                    

 Fan-tray 1:                                                                   

 Status    : Absent                                                             

 Fan-tray 2:                                                                   

 Status    : Normal                                                            

 Fan number: 5                                                                 

 Fan mode  : Auto                                                              

 Airflow Direction: Front-to-back                                              

 Fan  Status      Speed(rpm)                                                   

 ---  ----------  ----------                                                   

  1   Normal      5023                                                         

  2   Normal      2675                                                         

  3   Normal      4474                                                         

  4   Normal      2609                                                         

  5   Normal      4232

表1-10 display fan命令显示信息描述表

字段

描述

Chassis 1

设备在IRF中的成员编号(IRF模式)

Fan-tray

风扇框编号

Status

风扇框的工作状态:

·     Absent:风扇框不在位

·     Normal:风扇框正常工作

·     Fault:风扇框故障

Fan mode

风扇工作模式

Airflow Direction

风道方向

Fan

风扇框中的风扇编号

Speed(rpm)

风扇转速,以rpm为单位

 

1.1.22  display memory

display memory命令用来显示内存使用情况。

【命令】

独立运行模式:

display memory [ slot slot-number [ cpu cpu-number ] ]

IRF模式:

display memory [ chassis chassis-number slot slot-number  [ cpu cpu-number ] ]

【视图】

任意视图

【缺省用户角色】

network-admin

network-operator

mdc-admin

mdc-operator

【参数】

slot slot-number:表示单板所在的槽位号,不指定时显示当前所有单板的内存使用情况。(独立运行模式)

chassis chassis-number slot slot-number:显示指定单板或PEX设备的内存使用情况。chassis-number表示IRF中的成员编号或IRF3中PEX设备的虚拟框号,slot-number表示单板所在的槽位号。不指定时该参数时,显示当前所有单板PEX设备的内存使用情况。(IRF模式)

cpu cpu-number:表示CPU编号。不指定该参数时,表示默认CPU。

【举例】

# 显示设备的内存使用情况。(独立运行模式)

<Sysname> display memory

The statistics about memory is measured in KB:

Slot 9:                                                                        

             Total      Used      Free    Shared   Buffers    Cached   FreeRatio

Mem:       1346244    704440    641804         0         0     26724       47.7%

-/+ Buffers/Cache:    677716    668528                                         

Swap:           0         0         0                                          

                                                                               

Slot 10:                                                                        

             Total      Used      Free    Shared   Buffers    Cached   FreeRatio

Mem:       1346244    386292    959952         0         0     26708       71.3%

-/+ Buffers/Cache:    359584    986660                                         

Swap:           0         0         0                                          

                                                                               

Slot 11:                                                                        

             Total      Used      Free    Shared   Buffers    Cached   FreeRatio

Mem:       1350340    385680    964660         0         0     26708       71.4%

-/+ Buffers/Cache:    358972    991368                                          

Swap:           0         0         0                                          

                                                                               

Slot 17:                                                                        

             Total      Used      Free    Shared   Buffers    Cached   FreeRatio

Mem:       8061524   1292968   6768556         0        68    600776       84.0%

-/+ Buffers/Cache:    692124   7369400                                         

Swap:           0         0         0

# 显示设备的内存使用情况。(IRF模式)

<Sysname> display memory

The statistics about memory is measured in KB:                                 

Chassis 1 Slot 9:                                                              

             Total      Used      Free    Shared   Buffers    Cached   FreeRatio

Mem:       1362304    648768    713536         0         0     14376       52.4%

-/+ Buffers/Cache:    634392    727912                                         

Swap:           0         0         0                                          

                                                                               

Chassis 1 Slot 10:                                                             

             Total      Used      Free    Shared   Buffers    Cached   FreeRatio

Mem:       1362304    321588   1040716         0         0     14376       76.4%

-/+ Buffers/Cache:    307212   1055092                                         

Swap:           0         0         0                                           

                                                                               

Chassis 1 Slot 11:                                                             

             Total      Used      Free    Shared   Buffers    Cached   FreeRatio

Mem:       1366400    321440   1044960         0         0     14376       76.5%

-/+ Buffers/Cache:    307064   1059336                                         

Swap:           0         0         0                                           

                                                                               

Chassis 1 Slot 17:                                                             

             Total      Used      Free    Shared   Buffers    Cached   FreeRatio

Mem:       8143312    915496   7227816         0        68    265956       88.8%

-/+ Buffers/Cache:    649472   7493840                                         

Swap:           0         0         0

表1-11 display memory命令显示信息描述表

字段

描述

The statistics about memory is measured in KB:

系统内存使用情况,以下统计信息均以KB为单位

Slot

单板所在的槽位号(独立运行模式)

Chassis x Slot x

单板所在的槽位号(IRF模式)

Mem

内存使用信息

Total

系统可分配的物理内存的大小

设备总物理内存分为不可分配物理内存和可分配物理内存。其中,不可分配物理内存用于内核代码段存储、内核管理开销等;可分配物理内存用于支撑业务模块的运行、文件存储等操作。不可分配内存的大小由设备根据系统运行需要自动计算划分,可分配物理内存的大小等于设备总物理内存减去不可分配内存的大小

Used

整个系统已用的物理内存大小

Free

整个系统可用的物理内存大小

Shared

多个进程共享的物理内存总额

Buffers

已使用的文件缓冲区的大小

Cached

高速缓冲寄存器已使用的内存大小

FreeRatio

整个系统物理内存的空闲率

-/+ Buffers/Cache

-/+ Buffers/Cache:Used = Mem:Used – Mem:Buffers – Mem:Cached,表示应用程序已用的物理内存大小

-/+Buffers/Cache:Free = Mem:Free + Mem:Buffers + Mem:Cached,表示应用程序可用的物理内存大小

Swap

交换分区的使用信息

 

1.1.23  display memory-threshold

display memory-threshold命令用来显示内存告警门限相关信息。

【命令】

独立运行模式:

display memory-threshold [ slot slot-number  [ cpu cpu-number ] ]

IRF模式:

display memory-threshold [ chassis chassis-number slot slot-number  [ cpu cpu-number ] ]

【视图】

任意视图

【缺省用户角色】

network-admin

mdc-admin

【参数】

slot slot-number:表示单板所在的槽位号。不指定该参数时,表示主用主控板。(独立运行模式)

chassis chassis-number slot slot-number:显示指定单板或PEX设备的内存告警门限相关信息。chassis-number表示IRF中的成员编号或IRF3PEX设备的虚拟框号,slot-number表示单板所在的槽位号。不指定该参数时,显示主用主控板的告警门限相关信息。(IRF模式)

cpu cpu-number:表示CPU编号。不指定该参数时,表示默认CPU。

【使用指导】

当设备已经使用的物理内存大小超过内存某个告警门限阈值时,系统会认为发生了一次该类型内存异常,并记录第一次、最近一次发生异常的时间,以及这段时间内发生的该类异常的次数。如果想了解该类异常的详细情况,请查看日志信息,可按日志摘要关键字“MEM_EXCEED_THRESHOLD”或“MEM_BELOW_THRESHOLD”进行搜索。

【举例】

# 显示内存告警门限相关信息。

<Sysname> display memory-threshold

Memory usage threshold: 100%                                                   

Free memory threshold:                                                         

    Minor: 96M                                                                 

    Severe: 64M                                                                

    Critical: 48M                                                              

    Normal: 128M                                                               

Current memory state: Normal                                                   

Event statistics:                                                              

 [Back to normal state]                                                        

    First notification: 0.0                                                     

    Latest notification: 0.0                                                   

    Total number of notifications sent: 0                                      

 [Enter minor low-memory state]                                                 

    First notification at: 0.0                                                 

    Latest notification at: 0.0                                                

    Total number of notifications sent: 0                                       

 [Back to minor low-memory state]                                              

    First notification at: 0.0                                                 

    Latest notification at: 0.0                                                 

    Total number of notifications sent: 0                                      

 [Enter severe low-memory state]                                               

    First notification at: 0.0                                                 

    Latest notification at: 0.0                                                

    Total number of notifications sent: 0                                      

 [Back to severe low-memory state]                                             

    First notification at: 0.0                                                 

    Latest notification at: 0.0                                                

    Total number of notifications sent: 0                                      

 [Enter critical low-memory state]                                             

    First notification at: 0.0                                                 

    Latest notification at: 0.0                                                

    Total number of notifications sent: 0   

表1-12 display memory-threshold命令显示信息描述表

字段

描述

Memory usage threshold

内存利用率阈值

Free memory threshold

         Minor:

         Severe:

         Critical:

         Normal:

剩余内存门限阈值:

·     Minor:一级告警门限,单位为MB

·     Severe:二级告警门限,单位为MB

·     Critical:三级告警门限,单位为MB

·     Normal:恢复到正常状态的阈值,单位为MB

Current memory state

系统当前内存使用状态:

·     Normal:正常状态

·     Minor:一级告警门限状态

·     Severe:二级告警门限状态

·     Critical:三级告警门限状态

Event statistics:

门限事件统计信息,事件分为:

·     Back to normal state:内存恢复到正常状态

·     Enter minor low-memory state:进入一级告警门限状态

·     Back to minor low-memory state:恢复到一级告警门限状态

·     Enter severe low-memory state:进入二级告警门限状态

·     Back to severe low-memory state:恢复到二级告警门限状态

·     Enter critical low-memory state:进入三级告警门限状态

First notification at

事件第一次发生的时间,格式yyyy-mm-dd hh:mm:ss.msec

Lastest notification at

事件最近一次发生的时间,格式yyyy-mm-dd hh:mm:ss.msec

Total number of notifications sent

事件发生的总次数

 

1.1.24  display power

display power命令用来显示设备电源的信息。

【命令】

独立运行模式:

display power [ power-id ]

IRF模式:

display power [ chassis { actual-chassis-number | virtual-chassis-number slot slot-number } [ power-id ] ]

【视图】

任意视图

【缺省用户角色】

network-admin

network-operator

mdc-admin

mdc-operator

【参数】

chassis actual-chassis-number:显示指定成员设备上电源的信息。actual-chassis-number表示设备在IRF中的成员编号。

chassis virtual-chassis-number slot slot-number:显示指定PEX设备上电源的信息。virtual-chassis-number表示PEX设备的虚拟框号,slot-number取值只能为0。

power-id:查看指定电源的信息。power-id表示电源的编号。不指定该参数时,表示所有电源。

【使用指导】

不指定成员设备和PEX设备时,显示所有成员设备及PEX设备上的电源的信息。

【举例】

# 显示设备电源模块的信息。(独立运行模式)

<Sysname> display power

 PowerID State          Current(A)  Voltage(V)  Power(W)                       

 1       Normal           7.80       54.02      421.35                         

 2       Normal           9.20       53.99      496.70                         

 3       Absent            --          --          --                          

 4       Absent            --          --          --                          

 5       Absent            --          --          --                          

 6       Absent            --          --          --                          

 7       Absent            --          --          --                          

 8       Absent            --          --          --

# 显示设备电源模块的信息。(IRF模式)

<Sysname> display power

 Chassis 1:

 PowerID State          Current(A)  Voltage(V)  Power(W)                       

 1       Normal           7.80       54.02      421.35                         

 2       Normal           9.20       53.99      496.70                         

 3       Absent            --          --          --                          

 4       Absent            --          --          --                          

 5       Absent            --          --          --                          

 6       Absent            --          --          --                          

 7       Absent            --          --          --                          

 8       Absent            --          --          --

表1-13 display power命令显示信息描述表

字段

描述

Chassis 1

设备在IRF中的成员编号

PowerID

电源模块编号

State

电源模块的工作状态:

·     Absent:电源模块不在位

·     Normal:电源模块正常工作

·     Fault:电源模块故障

Current(A)

输入电流,以安为单位

Voltage(V)

输入电压,以伏为单位

Power(W)

电源功率,以瓦为单位

--

表示不支持显示此项

 

1.1.25  display scheduler job

display scheduler job命令用来查看Job的配置信息,包括Job的名称和分配的命令。

【命令】

display scheduler job [ job-name ]

【视图】

任意视图

【缺省用户角色】

network-admin

network-operator

mdc-admin

mdc-operator

【参数】

job-name:Job的名称,为1~47个字符的字符串,区分大小写。不指定该参数时,则显示所有Job的配置信息。

【举例】

# 查看所有Job的配置信息。

<Sysname> display scheduler job

Job name: saveconfig

 copy startup.cfg backup.cfg

 

Job name: backupconfig

 

Job name: creat-VLAN100

 system-view

 vlan 100

以上显示信息表明,设备当前配置了3个Job,分别显示了Job的名称,以及为Job分配的命令(如果没有为Job分配命令,则只显示Job的名称),不同Job间用空行分隔。

1.1.26  display scheduler logfile

display scheduler logfile命令用来显示Schedule日志文件的相关信息,包括Job的名称、对应的Schedule的名称、执行时间以及执行结果。

【命令】

display scheduler logfile

【视图】

任意视图

【缺省用户角色】

network-admin

network-operator

mdc-admin

mdc-operator

【举例】

# 显示Schedule日志文件的相关信息。

<Sysname> display scheduler logfile

Logfile Size: 1902 Bytes.

 

Job name        : shutdown

Schedule name   : shutdown

Execution time  : Tue Dec 27 10:44:42 2013

Completion time : Tue Dec 27 10:44:47 2013

--------------------------------- Job output -----------------------------------

<Sysname>system-view

System View: return to User View with Ctrl+Z.

[Sysname]interface rang ten-gigabitethernet 1/0/1 to ten-gigabitethernet 1/0/3

[Sysname-if-range]shutdown

表1-14 display scheduler logfile命令显示信息描述表

字段

描述

Logfile Size

Schedule日志文件的大小,单位为字节

Job name

Job的名称

Schedule name

Schedule的名称

Execution time

开始执行Job的时间

Completion time

Job执行结束的时间(没有调度的或者没有分配命令的Job,均不会显示该信息)

Job output

Job中的命令执行时的输出信息

 

【相关命令】

·     reset scheduler logfile

1.1.27  display scheduler reboot

display scheduler reboot命令用来查看定时重启功能的相关配置。

【命令】

display scheduler reboot

【视图】

任意视图

【缺省用户角色】

network-admin

network-operator

mdc-admin

mdc-operator

【举例】

# 查看定时重启功能的相关配置。

<Sysname> display scheduler reboot

System will reboot at 16:32:00 05/23/2013 (in 1 hours and 39 minutes).

【相关命令】

·     scheduler reboot at

·     scheduler reboot delay

1.1.28  display scheduler schedule

display scheduler schedule命令用来查看Schedule的相关信息。

【命令】

display scheduler schedule [ schedule-name ]

【视图】

任意视图

【缺省用户角色】

network-admin

network-operator

mdc-admin

mdc-operator

【参数】

schedule-name:Schedule的名称,为1~47个字符的字符串,区分大小写。如果不指定该参数,则显示所有Schedule的信息。

【举例】

# 查看所有Schedule的信息。

<Sysname> display scheduler schedule

Schedule name        : shutdown

Schedule type        : Run once after 0 hours 2 minutes

Start time           : Tue Dec 27 10:44:42 2011

Last execution time  : Tue Dec 27 10:44:42 2011

Last completion time : Tue Dec 27 10:44:47 2011

Execution counts     : 1

-----------------------------------------------------------------------

Job name                                          Last execution status

shutdown                                          Successful

表1-15 display scheduler schedule命令显示信息描述表

字段

描述

Schedule name

Schedule的名称

Schedule type

Schedule的执行时间配置。如果没有为Schedule配置执行时间,则不会显示该信息

Start time

Schedule第一次开始执行的时间。如果没有为Schedule配置执行时间,则不会显示该信息

Last execution time

Schedule上一开始执行的时间

·     如果没有为Schedule配置执行时间,则不会显示该信息

·     如果还没有执行,则显示Yet to be executed

Last completion time

Schedule上一次执行完成的时间。如果没有为Schedule配置执行时间,则不会显示该信息

Execution counts

Schedule已经执行的次数。如果Schedule还没有执行,则不会显示该信息

Job name

Schedule下关联的Job的名称

Last execution status

Job上一次被执行的状态(Job下分配的命令是否执行以及执行结果,请通过display scheduler logfile命令查看)

·     Successful:表示执行成功

·     Failed:表示执行失败

·     Waiting:表示正在等待被执行

·     In process:表示正在执行

·     -NA-:表示还没有到执行时间

 

1.1.29  display switch-mode status

display switch-mode status用于查看交换机所有单板当前的工作模式。(独立运行模式)

display switch-mode status chassis用于查看某一成员设备所有单板当前的工作模式。(IRF模式)

【命令】

独立运行模式:

display switch-mode status

IRF模式:

display switch-mode status chassis chassis-number

【视图】

任意视图

【缺省用户角色】

network-admin

network-operator

mdc-admin

mdc-operator

【参数】

chassis chassis-number:显示指定成员设备上所有单板当前的工作模式。chassis-number表示设备在IRF中的成员编号。(IRF模式)

【使用指导】

·     display switch-mode status用于查看交换机所有单板当前的工作模式。(独立运行模式)

·     display switch-mode status chassis用于查看某一成员设备所有单板当前的工作模式。(IRF模式)

【举例】

# 查看交换机所有业务板的工作模式。(独立运行模式)

<Sysname> display switch-mode status

 

LPU switch mode:

Slot    Current        Config                                                  

 1      NORMAL         NORMAL                                                  

 3      NORMAL         NORMAL                                                  

 5      NORMAL         STANDARD-IPV6                                                

 7      NORMAL         STANDARD-IPV6

# 查看IRF中1号成员设备的所有业务板的工作模式。(IRF模式)

<Sysname>display switch-mode status chassis 1

 

LPU switch mode:                                                               

Slot    Current        Config                                                  

 1      NORMAL         NORMAL                                                  

 3      NORMAL         NORMAL                                                  

 5      NORMAL         STANDARD-IPV6                                                

 7      NORMAL         STANDARD-IPV6

表1-16 display switch-mode status显示信息描述表

字段

说明

LPU switch mode

业务板工作模式

Slot

单板槽位号

Current

单板当前的工作模式

Config

用户配置的单板工作模式

*

单板不支持该工作模式

 

【相关命令】

·     switch-mode

1.1.30  display system-working-mode

display system-working-mode命令用来显示设备的工作模式。

【命令】

display system-working-mode

【视图】

任意视图

【缺省用户角色】

network-admin

network-operator

mdc-admin

mdc-operator

【举例】

# 显示设备的工作模式。

<Sysname> display system-working-mode

The current system working mode is standard.

The next system working mode is advance.

1.1.31  display transceiver alarm

display transceiver alarm命令用来显示可插拔接口模块的当前故障告警信息。

【命令】

display transceiver alarm interface [ interface-type interface-number ]

【视图】

任意视图

【缺省用户角色】

network-admin

network-operator

mdc-admin

mdc-operator

【参数】

interface [ interface-type interface-number ]:显示接口上插入的可插拔接口模块的当前故障告警信息。interface-type interface-number表示接口类型和接口编号,如果不指定该参数,表示所有接口。

【使用指导】

目前,使用的可插拔接口模块可能出现的故障告警信息见表1-17。如果没有故障,则显示为None。

表1-17 display transceiver alarm命令输出信息描述表

字段

描述

SFP/SFP+

RX loss of signal

接收信号丢失

RX power high

接收光功率高告警

RX power low

接收光功率低告警

TX fault

发送错误

TX bias high

偏置电流高告警

TX bias low

偏置电流低告警

TX power high

发送光功率高告警

TX power low

发送光功率低告警

Temp high

温度高告警

Temp low

温度低告警

Voltage high

电压高告警

Voltage low

电压低告警

Transceiver info I/O error

模块信息读写错误

Transceiver info checksum error

模块信息校验和错误

Transceiver type and port configuration mismatch

模块类型和端口配置不匹配

Transceiver type not supported by port hardware

端口不支持该模块类型

QSFP+

RX loss signal (channel x)

通道x接收信号丢失

TX fault (channel x)

通道x发送错误

TX loss signal (channel x)

通道x发送信号丢失

RX power high (channel x)

通道x接收光功率高告警

RX power low (channel x)

通道x接收光功率低告警

TX bias high (channel x)

通道x偏置电流高告警

TX bias low (channel x)

通道x偏置电流低告警

Temp high

温度高告警

Temp low

温度低告警

Voltage high

电压高告警

Voltage low

电压低告警

Transceiver info I/O error

模块信息读写错误

Transceiver info checksum error

模块信息校验错误

Transceiver type and port configuration mismatch

模块类型和端口配置不匹配

Transceiver type not supported by port hardware

端口不支持该模块类型

CFP

TX jitter PLL unlocked

发送Jitter PLL失锁

TX CMU unlocked

发送CMU失锁

Overloaded

负载过大

Loss of REFCLK input

参考时钟未输入

Channel signals out of alignment

主机通道信号不对齐

PLD or flash initialization error

初始化错误

Power supply fault

电源错误

CFP checksum error

校验和错误

TX bias high

偏置电流高

TX bias low

偏置电流低

Temp high

温度高

Temp low

温度低

Voltage high

电压高

Voltage low

电压低

RX signal loss in channel x

通道x接收信号丢失

RX IC unlocked in channel x

通道x接收IC时钟失锁

RX FIFO error in channel x

通道x接收FIFO错误

TX signal loss in channel x

通道x发送信号失效

TX IC unlocked in channel x

通道x发送IC时钟失锁

TX FIFO error in channel x

主机通道x发送FIFO错误

TX IC unlocked in channel x

主机通道x发送IC时钟失锁

APD supply fault in channel x

通道xAPD错误

TEC fault in channel x

通道xTEC错误

Wavelength unlocked in channel x

通道x光信号波长失锁

RX power high in lane x

通道x接收光功率高

RX power low in lane x

通道x接收光功率低

TX power high in lane x

通道x发送光功率高

TX power low in lane x

通道x发送光功率低

TX bias high in lane x

通道x偏置电流高

TX bias low in lane x

通道x偏置电流低

Temp high in lane x

通道x温度高

Temp low in lane x

通道x温度低

Transceiver info I/O error

模块读写错误

Transceiver info checksum error

模块信息校验和错误

Transceiver type and port configuration mismatched

模块类型和端口配置不匹配

Transceiver type not supported

端口不支持该模块类型

 

【举例】

# 显示接口Ten-GigabitEthernet1/0/1上插入的可插拔接口模块的当前故障告警信息。

<Sysname> display transceiver alarm interface ten-gigabitethernet 1/0/1

Ten-GigabitEthernet1/0/1 transceiver current alarm information:

  RX loss of signal

  RX power low

表1-18 display transceiver alarm显示信息描述表

字段

描述

transceiver current alarm information

接口光模块当前故障告警信息

RX loss of signal

接收信号丢失

RX power low

接收光功率低告警

 

1.1.32  display transceiver diagnosis

display transceiver diagnosis命令用来显示可插拔光模块的数字诊断参数的当前测量值。

【命令】

display transceiver diagnosis interface [ interface-type interface-number ]

【视图】

任意视图

【缺省用户角色】

network-admin

network-operator

mdc-admin

mdc-operator

【参数】

interface [ interface-type interface-number ]:显示接口上插入的可插拔光模块的数字诊断参数的当前测量值。interface-type interface-number表示接口类型和接口编号,如果不指定该参数,表示所有接口。

【举例】

# 显示接口Ten-GigabitEthernet1/0/1上插入的可插拔光模块的数字诊断参数的当前测量值。

<Sysname> display transceiver diagnosis interface ten-gigabitethernet 1/0/1

Ten-GigabitEthernet1/0/1 transceiver diagnostic information:

  Current diagnostic parameters:

    Temp(°C)  Voltage(V)  Bias(mA)  RX power(dBm)  TX power(dBm)

    36        3.31        6.13      -35.64          -5.19

表1-19 display transceiver diagnosis显示信息描述表

字段

描述

transceiver diagnostic information

接口插入的光模块的数字诊断信息

Current diagnostic parameters

当前的诊断参数

Temp.(°C)

数字诊断参数——温度,单位为°C,精确到1°C

Voltage(V)

数字诊断参数——电压,单位为V,精确到0.01V

Bias(mA)

数字诊断参数——偏置电流,单位为mA,精确到0.01mA

RX power(dBm)

数字诊断参数——接收光功率,单位为dBm,精确到0.01dBm

TX power(dBm)

数字诊断参数——发送光功率,单位为dBm,精确到0.01dBm

 

1.1.33  display transceiver interface

display transceiver interface命令用来显示可插拔接口模块的主要特征参数。

【命令】

display transceiver interface [ interface-type interface-number ]

【视图】

任意视图

【缺省用户角色】

network-admin

network-operator

mdc-admin

mdc-operator

【参数】

interface-type interface-number:显示接口上插入的可插拔接口模块的主要特征参数。interface-type interface-number表示接口类型和接口编号,如果不指定该参数,表示所有接口。

【举例】

# 显示接口Ten-GigabitEthernet1/0/1上插入的可插拔接口模块的主要特征参数。

<Sysname> display transceiver interface ten-gigabitethernet 1/0/1

Ten-GigabitEthernet1/0/1 transceiver information:

  Transceiver Type              : 1000_BASE_SX_SFP

  Connector Type                : LC

  Wavelength(nm)                : 850

  Transfer Distance(m)          : 550(50um),270(62.5um)

  Digital Diagnostic Monitoring : YES

  Vendor Name                   : H3C

  Ordering Name                 : SFP-GE-SX-MM850

表1-20 display transceiver interface命令显示信息描述表

字段

描述

transceiver information

可插拔接口模块信息

Transceiver Type

可插拔接口模块的物理型号

Connector Type

可插拔接口模块的连接器类型,包括:

·     MPO(Multi-fiber Push On)

·     LC(LC Connector,Lucent公司推出的1.25mm/RJ45锁紧式光纤连接器)

·     RJ-45

Wavelength(nm)

·     光模块:显示发送激光中心波长,单位nm;对于支持多条不同波长光路的模块(例如10GBASE-LX4模块),各个波长值之间用逗号分隔

·     电模块:显示为“N/A”

Transfer Distance(xx)

传输距离,xx为传输距离的单位,对于单模模块xx为km,对于其他模块xx为m。当模块支持多种传输介质时,各个传输距离值之间用逗号分隔。距离值后面括号里包含对应的“传输介质”。下面是各个介质的名称:

·     9um:表示9/125um单模光纤

·     50um:表示50/125um多模光纤

·     62.5um:表示62.5/125um多模光纤

·     TP:表示双绞线

Digital Diagnostic Monitoring

对数字诊断功能的支持情况,其中:

·     YES:表示支持数字诊断

·     NO:表示不支持数字诊断

Vendor Name

模块生产或定制厂商名称

Ordering Name

可插拔接口模块的对外型号

 

1.1.34  display transceiver manuinfo

display transceiver manuinfo命令用于显示可插拔接口模块的部分电子标签信息。

【命令】

display transceiver manuinfo interface [ interface-type interface-number ]

【视图】

任意视图

【缺省用户角色】

network-admin

network-operator

mdc-admin

mdc-operator

【参数】

interface [ interface-type interface-number ]:显示接口上插入的可插拔接口模块的部分电子标签信息。interface-type interface-number表示接口类型和接口编号,如果不指定该参数,表示所有接口。

【举例】

# 显示接口Ten-GigabitEthernet1/0/1上插入的可插拔接口模块的部分电子标签信息。

<Sysname> display transceiver manuinfo interface ten-gigabitethernet 1/0/1

Ten-GigabitEthernet1/0/1 transceiver manufacture information:

  Manu. Serial Number  : 213410A0000054000251

  Manufacturing Date   : 2012-09-01

  Vendor Name          : H3C

表1-21 display transceiver manuinfo命令显示信息描述表

字段

描述

Manu. Serial Number

在生产过程中生成的序列号

Manufacturing Date

写入电子标签的日期

Vendor Name

厂商名称

 

1.1.35  display version

display version命令用来显示系统版本信息。

【命令】

display version

【视图】

任意视图

【缺省用户角色】

network-admin

network-operator

mdc-admin

mdc-operator

【举例】

# 查看系统版本信息(不同设备的版本信息不同,请以设备的实际情况为准,此处略)。

<Sysname> display version

1.1.36  display version-update-record

display version-update-record命令用来显示主用主控板启动软件包版本更新操作的记录。(独立运行模式)

display version-update-record命令用来显示全局主用主控板启动软件包版本更新操作的记录。(IRF模式)

【命令】

display version-update-record

【视图】

任意视图

【缺省用户角色】

network-admin

network-operator

mdc-admin

mdc-operator

【使用指导】

设备启动时会记录当前使用的启动软件包版本信息,如果在运行过程中进行启动软件包版本更新操作,系统会记录该次更新的简要信息,包括升级时间和版本,以便管理员了解相关信息。设备重启这些记录也不会被删除。

目前最多可以保存10条更新记录。

【举例】

# 显示设备启动软件包版本更新操作的记录。

<Sysname> display version-update-record

  Name                                   Version                  Compile time       

Record 1  (updated on Sep 26 2014 at 10:18:12):                                

* S12500F-CMW710-BOOT-E1030L16.bin       7.1.045 Ess 1030L16 Aug 13 2014 18:18:53                                                                               

* S12500F-CMW710-SYSTEM-E1030L16.bin     7.1.045 Ess 1030L16 Aug 13 2014 18:18:53

表1-22 display version-update-record命令显示信息描述表

字段

描述

Name

软件包的名称

Version

软件包的版本号

Compile time

版本编译时间

Record 1

最近的第n次更新的时间,Record 1为最新的一次更新

*

表示软件包的版本和升级前的版本有变化,没有星号的表示版本没有变化

 

【相关命令】

·     reset version-update-record

1.1.37  header

header命令用来设置欢迎信息。

undo header命令用来关闭欢迎信息。

【命令】

header { incoming | legal | login | motd | shell } text

undo header { incoming | legal | login | motd | shell }

【缺省情况】

没有配置任何欢迎信息。

【视图】

系统视图

【缺省用户角色】

network-admin

mdc-admin

【参数】

incoming:设置Modem登录用户登录进入用户视图时的欢迎信息。如果要求认证,则欢迎信息在通过认证后输出。

legal:设置登录终端界面前的授权信息,在输入认证用户名和密码前输出。

login:设置登录验证时的欢迎信息。

motd:设置登录终端界面前的欢迎信息。该参数的支持情况与设备的型号有关,请以设备的实际情况为准。

shell:设置非Modem登录用户登录进入用户视图时的欢迎信息。

text:输入欢迎信息的内容。内容的输入支持单行和多行两种方式,具体输入规则请参见“基础配置指导”中的“设备管理”。

【举例】

# 先后配置incominglegalloginmotdshell欢迎信息,并验证配置效果。

<Sysname> system-view

[Sysname] header incoming

Please input banner content, and quit with the character '%'.

Welcome to incoming(header incoming)%

[Sysname] header legal

Please input banner content, and quit with the character '%'.

Welcome to legal (header legal)%

[Sysname] header login

Please input banner content, and quit with the character '%'.

Welcome to login(header login)%

[Sysname] header motd

Please input banner content, and quit with the character '%'.

Welcome to motd(header motd)%

[Sysname] header shell

Please input banner content, and quit with the character '%'.

Welcome to shell(header shell)%

本例中,“%”为text的起始/结束字符,在显示文本后输入“%”表示文本结束,退出header命令。作为起始与结束字符,“%”不会成为所设置欢迎信息的一部分。

采用Telnet方式远程登录设备,测试以上设置(只有设置了登录认证之后,才会显示login欢迎信息)。

******************************************************************************

* Copyright (c) 2004-2014 Hangzhou H3C Tech. Co., Ltd. All rights reserved.  *

* Without the owner's prior written consent,                                 *

* no decompiling or reverse-engineering shall be allowed.                    *

******************************************************************************

 

 

Welcome to legal (header legal)

 Press Y or ENTER to continue, N to exit.

 

Welcome to login(header login)                                                 

                                                                               

Password:                                                                      

                                                                               

                                                                               

Welcome to motd(header motd)                                                   

                                                                               

                                                                               

                                                                               

Welcome to shell(header shell)

1.1.38  job

job命令用来为Schedule分配Job。

undo job命令用来将Job从Schedule中删除。

【命令】

job job-name

undo job job-name

【缺省情况】

没有为Schedule分配Job。

【视图】

Schedule视图

【缺省用户角色】

network-admin

mdc-admin

【参数】

job-name:Job的名称,为1~47个字符的字符串,区分大小写。

【使用指导】

多次执行该命令,可以为Schedule分配多个Job。多个Job在Schedule指定的时间同时执行,没有先后顺序。

分配的Job必须是设备上已经创建的Job,否则不能分配。Job可以通过scheduler job命令来创建。

【举例】

# 为Schedule分配一个名称为save-job的Job。

<Sysname> system-view

[Sysname] scheduler schedule saveconfig

[Sysname-schedule-saveconfig] job save-job

【相关命令】

·     scheduler job

·     scheduler schedule

1.1.39  memory-threshold

memory-threshold命令用来配置剩余内存告警的门限值。

undo memory-threshold命令用来恢复剩余内存告警的门限值。

【命令】

独立运行模式:

memory-threshold [ slot slot-number [ cpu cpu-number ] ] minor minor-value severe severe-value critical critical-value normal normal-value

undo memory-threshold [ slot slot-number [ cpu cpu-number ] ]

IRF模式:

memory-threshold [ chassis chassis-number slot slot-number [ cpu cpu-number ] ] minor minor-value severe severe-value critical critical-value normal normal-value

undo memory-threshold [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]

【缺省情况】

一级告警门限为96MB,二级告警门限为64MB,三级告警门限为48MB,系统恢复到正常的内存门限为128MB。

【视图】

系统视图

【缺省用户角色】

network-admin

mdc-admin

【参数】

minor minor-value:一级告警门限,单位为兆字节(MB);该值应小于等于单板内存大小;为0则表示关闭该级门限告警功能。

severe severe-value:二级告警门限,单位为兆字节(MB);该值必须小于等于一级告警门限;为0则表示关闭该级门限告警功能。

critical critical-value:三级告警门限,单位为兆字节(MB);该值必须小于等于二级告警门限;为0则表示关闭该级门限告警功能。

normal normal-value:系统内存恢复正常状态时的内存大小,单位为兆字节(MB);该值必须大于等于一级告警门限,且小于等于实际内存大小。

slot slot-number:表示单板所在的槽位号,不指定该参数时,表示主用主控板。(独立运行模式)

chassis chassis-number slot slot-number:配置指定单板或PEX设备的内存告警门限。chassis-number表示设备在IRF中的成员编号或IRF3中PEX设备的虚拟框号,slot-number表示单板所在的槽位号。不指定该参数时,表示配置主用主控板的内存告警门限。(IRF模式)

cpu cpu-number:表示CPU编号。不指定该参数时,表示默认CPU。

【使用指导】

系统实时监控系统剩余空闲内存大小,当条件达到时,就产生相应的告警/告警解除通知,以便通知关联的业务模块/进程采取相应的措施,以便最大限度的利用内存,又能保证设备的正常运行。

设备支持三级告警门限:

·     当系统剩余空闲内存小于等于一级告警门限时,产生一级告警;

·     当系统剩余空闲内存小于等于二级告警门限时,产生二级告警;

·     当系统剩余空闲内存小于等于三级告警门限时,产生三级告警。

·     当系统剩余空闲内存大于等于二级告警门限时,产生三级告警解除通知;

·     当系统剩余空闲内存大于等于一级告警门限时,产生二级告警解除通知;

·     当系统剩余空闲内存大于等于正常内存大小时,产生一级告警解除通知。

同一级别的告警/告警解除通知是交替进行的:当系统剩余空闲内存小于等于某级告警门限,设备产生相应级别的告警,后续只有该告警解除了,系统剩余空闲内存再次小于等于某级告警门限时,才会再次生成该级别的告警。

【举例】

# 一级、二级、三级告警门限分别为64MB、48MB、32MB,当系统剩余空闲内存大于96MB时,恢复到正常状态。

<Sysname> system-view

[Sysname] memory-threshold minor 64 severe 48 critical 32 normal 96

1.1.40  monitor cpu-usage enable

monitor cpu-usage enable命令用来开启CPU利用率历史记录功能。

undo monitor cpu-usage enable命令用来关闭CPU利用率历史记录功能。

【命令】

独立运行模式:

monitor cpu-usage enable [ slot slot-number [ cpu cpu-number ] ]

undo monitor cpu-usage enable [ slot slot-number [ cpu cpu-number ] ]

IRF模式:

monitor cpu-usage enable [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]

undo monitor cpu-usage enable [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]

【缺省情况】

CPU利用率历史记录功能处于开启状态。

【视图】

系统视图

【缺省用户角色】

network-admin

mdc-admin

【参数】

slot slot-number:表示单板所在的槽位号,不指定表示主用主控板。(独立运行模式)

chassis chassis-number slot slot-number:开启指定单板或PEX设备的CPU利用率历史记录功能。chassis-number表示IRF中的成员编号或IRF3中PEX设备的虚拟框号,slot-number表示单板所在的槽位号。不指定该参数时,表示开启主用主控板的CPU利用率历史记录功能。(IRF模式)

cpu cpu-number:表示CPU编号。不指定该参数时,表示默认CPU。

【举例】

# 打开CPU使用率历史记录功能。

<Sysname> system-view

[Sysname] monitor cpu-usage enable

【相关命令】

·     display cpu-usage

·     display cpu-usage configuration

·     display cpu-usage history

·     monitor cpu-usage interval

1.1.41  monitor cpu-usage interval

monitor cpu-usage interval命令用来配置CPU使用率历史记录采样周期。

【命令】

独立运行模式:

monitor cpu-usage interval interval-value [ slot slot-number [ cpu cpu-number ] ]

IRF模式:

monitor cpu-usage interval interval-value [ chassis chassis-number slot slot-number [ cpu cpu-number ] ]

【缺省情况】

CPU利用率历史记录采样周期为1分钟。

【视图】

系统视图

【缺省用户角色】

network-admin

mdc-admin

【参数】

interval-value:CPU利用率历史记录采用周期,取值为5Sec、1Min或者5Min。输入该参数时,请完整输入,否则,系统会提示参数错误。

slot slot-number:表示单板所在的槽位号,不指定表示主用主控板。(独立运行模式)

chassis chassis-number slot slot-number:配置指定单板或PEX设备的CPU使用率历史记录采样周期。chassis-number表示IRF中的成员编号或IRF3中PEX设备的虚拟框号,slot-number表单板所在的槽位号。不指定该参数时,表示配置主用主控板的CPU使用率历史记录采样周期。(IRF模式)

cpu cpu-number:表示CPU编号。不指定该参数时,表示默认CPU。

【举例】

# 配置CPU使用率历史记录采样周期为5秒。

<Sysname> system-view

[Sysname] monitor cpu-usage interval 5Sec

【相关命令】

·     display cpu-usage

·     display cpu-usage configuration

·     display cpu-usage history

·     monitor cpu-usage enable

1.1.42  monitor handshake-timeout disable-port

monitor handshake-timeout disable-port命令用于全局开启Port Down功能。

undo monitor handshake-timeout disable-port命令用于全局关闭Port Down功能。

【命令】

monitor handshake-timeout disable-port

undo monitor handshake-timeout disable-port

【缺省情况】

缺省情况下,Port Down功能处于开启状态。

【视图】

系统视图

【缺省用户角色】

network-admin

mdc-admin

【参数】

【使用指导】

本功能常用于以主备方式提供网络可靠性的双机环境中(例如VRRP)。开启本功能后,当主设备的主控板被拔出或异常重启时,系统将立即关闭主设备上的所有业务口,使业务快速切换到备用设备上。

说明

该功能配置成功后,只有当当前设备上已没有可用的主控板时才生效。

 

【举例】

# 全局开启Port Down功能。

<Sysname> system-view

System View: return to User View with Ctrl+Z.

[Sysname] monitor handshake-timeout disable-port

 

Set successful!

 

1.1.43  password-recovery enable

password-recovery enable命令用来使能密码恢复功能。

undo password-recovery enable命令用来关闭密码恢复功能。

【命令】

password-recovery enable

undo password-recovery enable

【缺省情况】

密码恢复功能处于使能状态。

【视图】

系统视图

【缺省用户角色】

network-admin

mdc-admin

【使用指导】

配置密码恢复功能后,当用户忘记Console口认证密码或者登录认证失败,导致无法使用命令行操作设备时,可通过BootWare菜单清除该认证密码,再继续使用设备;关闭密码恢复功能后,设备将处于一个安全性更高的状态,即当出现上述情况时,若想继续使用Console口对设备进行命令行操作,只能通过BootWare菜单选择将设备恢复为出厂配置之后方可继续操作,这样可以有效地防止非法用户获取启动配置文件。

BootWare菜单中支持配置的选项与密码恢复功能的配置有关,详见产品的相关手册。

【举例】

# 关闭密码恢复功能。

<Sysname> system-view

[Sysname] undo password-recovery enable

1.1.44  reboot

reboot命令用来重启指定单板或整个设备。(独立运行模式)

reboot命令用来重启指定成员设备或PEX设备。(IRF模式)

【命令】

独立运行模式:

reboot [ slot slot-number ] [ force ]

IRF模式:

reboot [ chassis chassis-number [ slot slot-number ] ] [ force ]

【视图】

用户视图

【缺省用户角色】

network-admin

mdc-admin

【参数】

chassis chassis-number:重启指定成员设备或PEX设备。chassis-number表示设备在IRF中的成员编号或IRF3中PEX设备的虚拟框号。

slot slot-number:表示单板所在的槽位号。

force:强制重启设备。

·     不指定该参数时,重启设备,系统会进行保护性检查(如启动文件是否存在,是否正在写磁盘等),若检查不通过则退出处理,不会重启设备。

·     指定该参数时,系统将不进行任何检查,直接执行重启操作。

【使用指导】

(1)     独立运行模式:

不指定slot参数,会导致整个设备重启。

需要注意的是:

·     重新启动会导致业务中断,请谨慎使用该命令。

·     如果主用启动文件损坏或者不存在,则不能通过reboot命令重启设备。此时,可以通过指定新的主用启动文件再重启。

·     如果设备在准备重启时,用户正在进行文件操作,为了安全起见,系统将不会执行此次重启操作。

·     使用force参数时,系统在重启时不会做任何保护性措施。重启后,可能导致文件系统损坏,请谨慎使用该参数。建议在系统故障或无法正常重启时,才使用该参数。

(2)     IRF模式:

·     不指定chassisslot参数,则会重启所有成员设备及PEX设备。

·     只指定chassis不指定slot参数,则会重启IRF中指定的成员设备或PEX设备。

·     同时指定chassisslot参数,则会重启IRF中指定的单板或PEX设备。

需要注意的是:

·     重新启动会导致业务中断,请谨慎使用该命令。

·     如果主用启动文件损坏或者不存在,则不能通过reboot命令重启设备。此时,可以通过指定新的主用启动文件再重启。

·     如果设备在准备重启时,用户正在进行文件操作,为了安全起见,系统将不会执行此次重启操作。

·     使用force参数时,系统在重启时不会做任何保护性措施。重启后,可能导致文件系统损坏,请谨慎使用该参数。建议在系统故障或无法正常重启时,才使用该参数。

【举例】

# 当配置没有变化时,重启设备。

<Sysname> reboot

 Start to check configuration with next startup configuration file, please wait.........DONE!

 This command will reboot the device. Continue? [Y/N]:y

 Now rebooting, please wait...

# 当配置有变化时,重启设备,并选择保存配置文件。

<Sysname> reboot

 Start to check configuration with next startup configuration file, please wait.........DONE!

 Current configuration may be lost after the reboot, save current configuration? [Y/N]:y

 Please input the file name(*.cfg)[flash:/startup.cfg]

 (To leave the existing filename unchanged, press the enter key):

 flash:/startup.cfg exists, overwrite? [Y/N]:y

 Validating file. Please wait...

 Configuration is saved to flash successfully.

 This command will reboot the device. Continue? [Y/N]:y

 Now rebooting, please wait...

# 当配置有变化时,重启设备,但不保存配置文件。

<Sysname> reboot

 Start to check configuration with next startup configuration file, please wait.........DONE!

 Current configuration may be lost after the reboot, save current configuration? [Y/N]:n

 This command will reboot the device. Continue? [Y/N]:y

 Now rebooting, please wait...

# 强制重启设备。

<Sysname> reboot force

A forced reboot might cause the storage medium to be corrupted. Continue? [Y/N]:y

 Now rebooting, please wait...

# 重启业务板(业务板所在的槽位号为2)。(独立运行模式)

<Sysname> reboot slot 2

 This command will reboot the specified slot, Continue? [Y/N]:y

 Now rebooting, please wait...

# 强制重启业务板(业务板所在的槽位号为2)。

<Sysname> reboot slot 2 force

A forced reboot might cause the storage medium to be corrupted. Continue? [Y/N]:y

 Now rebooting, please wait...

# 重启成员设备2。(IRF模式)

<Sysname> reboot chassis 2

 This command will reboot the specified chassis, Continue? [Y/N]:y

 Now rebooting, please wait...

# 强制重启成员设备2。

<Sysname> reboot chassis 2 force

A forced reboot might cause the storage medium to be corrupted. Continue? [Y/N]:y

 Now rebooting, please wait...

# 重启成员设备2上的2号业务板。(IRF模式)

<Sysname> reboot chassis 2 slot 2

 This command will reboot the specified slot, Continue? [Y/N]:y

 Now rebooting, please wait...

# 强制重启成员设备2上的2号业务板。

<Sysname> reboot chassis 2 slot 2 force

A forced reboot might cause the storage medium to be corrupted. Continue? [Y/N]:y

 Now rebooting, please wait...

1.1.45  reset asset-info

reset asset-info命令用来清除设备的用户资产信息。使用该命令,用户可以清除设备机箱、单板、风扇框或电源模块的资产信息。

【命令】

独立运行模式

reset asset-info { chassis | fan fan-id | power power-id | slot slot-number } [ csn | custom | department | description | location | service-date | state ]

IRF模式:

reset asset-info chassis chassis-number { chassis | fan fan-id | power power-id | slot slot-number } [ csn | custom| department | description | location | service-date | state ]

【视图】

系统视图

【缺省用户角色】

network-admin

network-operator

mdc-admin

mdc-operator

【参数】

chassis:清除设备机箱的用户资产信息。

fan fan-id:清除指定风扇框的用户资产信息。fan-id表示设备上风扇框的编号。

power power-id:清除指定电源模块的用户资产信息。power-id表示设备上电源模块的编号。

slot slot-number:清除指定单板的用户资产信息。slot-number表示设备上单板所在的槽位号。

csn:清除资产编号信息。

custom:清除用户自定义的资产信息。

department:清除资产的归属部门信息。

description:清除资产的描述信息。

location:清除资产的位置信息。

service-date:清除资产的启用时间信息。

state:清除资产的使用状态信息。

chassis chassis-number:清除指定设备的用户资产信息。chassis-number表示设备在IRF中的成员编号。(IRF模式)

说明

清除指定电源模块的用户资产信息时,命令行只支持csn参数。

 

【使用指导】

reset asset-info命令用来清除设备的用户资产信息。使用该命令,用户可以清除设备机箱、单板、风扇框或电源模块的资产信息。

当用户希望清除设备机箱、单板或风扇框的具体信息项目(比如资产编号、资产描述信息等)时,只需要选择该信息项目对应的命令行参数;不选择具体信息项目对应的参数时,清除的是该设备机箱、单板或风扇框的所有用户资产信息。

使用该命令清除指定风扇框或者电源模块的资产信息时,如果设备上无对应编号的风扇框或者电源模块,将返回风扇框或者电源模块不在位的提示信息。

【举例】

# 清除设备上0号风扇框的资产编号信息。(独立运行模式)

<Sysname> system-view

[Sysname] reset asset-info fan 0 csn

# 清除1号成员设备上0号风扇框的资产编号信息。(IRF模式)

<Sysname> system-view

[Sysname] reset asset-info chassis 1 fan 0 csn

【相关命令】

·     display asset-info

·     set asset-info

1.1.46  reset version-update-record

reset version-update-record命令用来清除主用主控板启动软件包版本更新操作的记录。(独立运行模式)

reset version-update-record命令用来清除全局主用主控板启动软件包版本更新操作的记录。(IRF模式)

【命令】

reset version-update-record

【视图】

系统视图

【缺省用户角色】

network-admin

mdc-admin

【举例】

# 清除设备启动软件包版本更新操作的记录。

<Sysname> system-view

[Sysname] reset version-update-record

【相关命令】

·     display version-update-record

1.1.47  reset scheduler logfile

reset scheduler logfile命令用来清除Schedule日志文件的相关信息。

【命令】

reset scheduler logfile

【缺省情况】

【视图】

用户视图

【缺省用户角色】

network-admin

mdc-admin

【举例】

# 清除Schedule日志文件的相关信息。

<Sysname> reset scheduler logfile

【相关命令】

·     display scheduler logfile

1.1.48  scheduler job

scheduler job命令用来创建Job并进入Job视图。如果Job已创建,则直接进入Job视图。

undo scheduler job命令用来删除已创建的Job。

【命令】

scheduler job job-name

undo scheduler job job-name

【缺省情况】

没有创建Job。

【视图】

系统视图

【缺省级别】

network-admin

mdc-admin

【参数】

job-name:Job的名称,为1~47个字符的字符串,区分大小写。

【使用指导】

一个Job可以被多个Schedule引用。Job视图下用户可以通过command命令为Job分配命令。

【举例】

# 创建名称为backupconfig的Job并进入Job视图。

<Sysname> system-view

[Sysname] scheduler job backupconfig

[Sysname-job-backupconfig]

【相关命令】

·     command

·     scheduler schedule

1.1.49  scheduler logfile size

scheduler logfile size命令用来设置Schedule日志文件的大小。

【命令】

scheduler logfile size value

【缺省情况】

Schedule日志文件的大小为16KB。

【视图】

系统视图

【缺省用户角色】

network-admin

mdc-admin

【参数】

value:Schedule日志文件的大小,取值范围为16~1024,单位是KB。

【使用指导】

Schedule日志文件用来记录Job下命令行的执行结果。如果该文件的大小超过了用户设置值,则系统会把老的记录删除,用来记录新的记录。如果要记录的日志信息超长,超过了日志文件的大小,则该日志超出的部分不会记录。

【举例】

# 设置Schedule日志文件的大小为32KB。

<Sysname> system-view

[Sysname] scheduler logfile size 32

【相关命令】

·     display scheduler logfile

1.1.50  scheduler reboot at

scheduler reboot at命令用来指定设备重启的具体时间和日期。

undo scheduler reboot命令用来取消重启时间的设置。

【命令】

scheduler reboot at time [ date ]

undo scheduler reboot

【缺省情况】

没有指定设备重启的具体时间和日期。

【视图】

用户视图

【缺省用户角色】

network-admin

mdc-admin

【参数】

time:设备重启的时间,格式为HH:MMHH代表小时,取值范围为0~23,MM代表分钟,取值范围为0~59。

date:设备重启的日期,格式为MM/DD/YYYY(月/日/年)或者YYYY/MM/DD(年/月/日)。

·     YYYY的取值范围为2000~2035;

·     MM的取值范围为1~12;

·     DD的取值范围与具体月份有关。

【使用指导】

如果没有指定date参数,并且:

·     设置的时间点在当前时间之后,则设备将在当天的该时间点重启;

·     设置的时间点在当前时间之前,则设备将在第二天的该时间点重启。

多次配置scheduler reboot atscheduler reboot delay命令,最新配置生效。

如果设备在准备重启时,用户正在进行文件操作,为了安全起见,系统将不会执行此次重启操作。

需要注意的是,该命令会使设备在将来的某个时间点重新启动,从而导致业务中断,请谨慎使用。

【举例】

# 假设系统的当前时间为2013年6月6日11:43,设置设备在当天中午12:00重启。

<Sysname> scheduler reboot at 12:00

Reboot system at 12:00:00 06/06/2013 (in 0 hours and 16 minutes). Confirm? [Y/N]:

【相关命令】

·     scheduler reboot delay

1.1.51  scheduler reboot delay

scheduler reboot delay命令用来配置重启设备的延迟时间。

undo scheduler reboot命令用来取消延时重启配置。

【命令】

scheduler reboot delay time

undo scheduler reboot

【缺省情况】

没有配置重启设备的延迟时间。

【视图】

用户视图

【缺省用户角色】

network-admin

mdc-admin

【参数】

time:设备重启的等待时延,格式为HH:MM(小时:分钟)或MM(分钟)。

·     使用HH:MM格式时,MM的取值范围为0~59,HH:MM的最大长度为6个字符。

·     使用MM格式时,最大长度为6个字符。

【使用指导】

如果设备在准备重启时,用户正在进行文件操作,为了安全起见,系统将不会执行此次重启操作。

需要注意的是,该命令会使设备在将来的某个时间点重新启动,从而导致业务中断,请谨慎使用。

【举例】

# 假设系统的当前时间为2011年6月6日11:48,配置设备在88分钟后重启。

<Sysname> scheduler reboot delay 88

Reboot system at 13:16 06/06/2011(in 1 hours and 28 minutes). Confirm? [Y/N]:

1.1.52  scheduler schedule

scheduler schedule命令用来创建Schedule并进入相应的Schedule视图。如果Schedule已创建,则直接进入Schedule视图。

undo scheduler schedule命令用来删除指定Schedule。

【命令】

scheduler schedule schedule-name

undo scheduler schedule schedule-name

【缺省情况】

没有创建Schedule。

【视图】

系统视图

【缺省用户角色】

network-admin

mdc-admin

【参数】

schedule-name:Schedule的名字,为1~47个字符的字符串,区分大小写。

【使用指导】

使用scheduler schedule命令可以配置定时执行任务,让设备在指定时间执行指定命令。

配置步骤如下:

(1)     使用scheduler job命令创建Job。

(2)     在Job视图下,使用command命令配置需要执行的命令。

(3)     使用scheduler schedule命令创建Schedule

(4)     在Schedule视图下,使用job命令为Schedule分配Job。一个Schedule下可以分配多个Job,但必须是已创建的Job,否则分配失败。

(5)     在Schedule视图下,使用user-role命令为Schedule配置用户角色。一个Schedule下最多可以分配64个角色。

(6)     在Schedule视图下,使用time attime once或者time repeating命令来配置任务执行的时间。一个Schedule下只能设置一个执行时间。

【举例】

# 创建名为saveconfig的Schedule。

<Sysname> system-view

[Sysname] scheduler schedule saveconfig

【相关命令】

·     job

·     time at

·     time once

·     time repeating

1.1.53  set asset-info

set asset-info命令用来设置设备的用户资产信息。使用该命令,用户可以根据自定义的规则为设备机箱、单板、风扇框及电源模块设置资产信息。

【命令】

独立运行模式:

set asset-info { chassis | fan fan-id | power power-id | slot slot-number } { csn csn-number | custom name value | department department | description description | location location | service-date date | state state }

IRF模式:

set asset-info chassis chassis-number { chassis | fan fan-id | power power-id | slot slot-number } { csn csn-number | custom name value | department department | description description | location location | service-date date | state state }

【视图】

系统视图

【缺省用户角色】

network-admin

network-operator

mdc-admin

mdc-operator

【参数】

chassis:设置设备机箱的用户资产信息。

fan fan-id:设置指定风扇框的用户资产信息。fan-id表示设备上风扇框的编号。

power power-id:设置指定电源模块的用户资产信息。power-id表示设备上电源模块的编号。

slot slot-number:设置指定单板的用户资产信息。slot-number表示设备上单板所在的槽位号。

csn csn-number:设置资产编号信息。csn-number表示用户设置的资产编号信息,为1~64字节的字符串。

custom name value:设置用户自定义的资产信息。name表示用户自定义的资产信息名称,value表示用户设置的资产信息内容。

department department:设置资产的归属部门信息。department表示用户设置的资产归属部门,为1~64字节的字符串。

description description:设置资产的描述信息。description表示用户设置的资产描述信息,为1~64字节的字符串。

location location:设置资产的位置信息。location表示用户设置的资产位置信息,为1~64字节的字符串。

service-date date:设置资产的启用时间信息。date表示用户设置的资产启用时间,为1~25字节的字符串。

state state:设置资产的使用状态信息。state表示用户设置的资产使用状态,为1~64字节的字符串。

chassis chassis-number:设置指定设备的用户资产信息。chassis-number表示设备在IRF中的成员编号。(IRF模式)

【使用指导】

使用该命令设置指定风扇框或者电源模块的资产信息时,如果设备上无对应编号的风扇框或者电源模块,将返回风扇框或者电源模块不在位的提示信息。

【举例】

# 设置设备上0号风扇框的资产编号为123456。(独立运行模式)

<Sysname> system-view

[Sysname] set asset-info fan 0 csn 123456

# 设置1号成员设备上0号风扇框的资产编号为123456。(IRF模式)

<Sysname> system-view

[Sysname] set asset-info chassis 1 fan 0 csn 123456

【相关命令】

·     display asset-info

·     reset asset-info

1.1.54  shutdown-interval

shutdown-interval命令用来设定定时检测的时间间隔。

undo shutdown-interval命令用来恢复缺省情况。

【命令】

shutdown-interval time

undo shutdown-interval

【缺省情况】

定时检测的时间间隔为30秒。

【视图】

系统视图

【缺省用户角色】

network-admin

mdc-admin

【参数】

time:定时检测的时间间隔,取值范围为1~300,单位为秒。

【使用指导】

某些协议模块在特定情况下会自动关闭某个端口,比如当使能了BPDU保护功能的端口收到配置消息时,MSTP协议模块将自动关闭该端口。同时,系统会启动一个检测定时器,如果直到定时器超时(即经过time秒之后),该端口仍处于关闭状态,协议模块则自动激活该端口,令其恢复到真实的物理状态。

需要注意的是,如果用户在端口定时检测过程中将检测时间间隔修改为T1,修改时刻距协议关闭端口时间间隔为T。若T<T1,则被关闭的端口会再经过T1-T时间后被恢复;若T>=T1,则被关闭的端口会立即恢复。例如当前time设置为30,当端口被协议模块关闭2秒(T=2)后,修改time为10(T1=10),则该接口会再经过8秒后被恢复;如果当前time为30,端口被协议模块关闭10秒后,修改time为2,则该端口会立即恢复。

【举例】

# 设定定时检测时间间隔为100秒。

<Sysname> system-view

[Sysname] shutdown-interval 100

1.1.55  switch-fabric isolate

switch-fabric isolate命令用来将网板从转发平面隔离出去,所有数据流量都不经过指定网板。

undo switch-fabric isolate命令用来恢复缺省情况。

【命令】

独立运行模式:

switch-fabric isolate slot slot-number [ channel channel-number ]

undo switch-fabric isolate slot slot-number  [ channel channel-number ]

IRF模式:

switch-fabric isolate chassis chassis-number slot slot-number [ channel channel-number ]

undo switch-fabric isolate chassis chassis-number slot slot-number [ channel channel-number ]

【缺省情况】

网板处于转发平面,数据流量会经过网板进行转发。

【视图】

系统视图

【缺省用户角色】

network-admin

mdc-admin

【参数】

slot slot-number:表示网板所在的槽位号。(独立运行模式)

chassis chassis-number slot slot-number:表示指定设备上的指定网板。(IRF模式)

channel channel-number:表示网板的指定通道号。若不指定该参数,将隔离整块网板。

【使用指导】

配置该功能后主控板与网板的正常通信,控制平面上协议报文的解析与协议的计算等功能均不受影响,从而保证了通过undo switch-fabric isolate 命令快速恢复网板的转发能力。

每块网板都有一定的转发带宽,隔离一块网板后会减少相应的转发带宽,使设备整体转发带宽降低。如果设备只装配了一块网板,隔离之后便不能转发报文,导致设备失去转发能力。

将网板的故障通道单独隔离出去,可以减小了因隔离整块网板对设备转发能力的影响。

【举例】

# 将10号槽位网板隔离。(独立运行模式)

<Sysname> system-view

[Sysname] switch-fabric isolate slot 10

The command will isolate the switch fabric from the system. Continue? [Y/N]y

# 将1号成员设备的10号槽位网板隔离的1号通道隔离。(IRF模式)

<Sysname> system-view

[Sysname] switch-fabric isolate chassis 1 slot 10 channel 1

The command will isolate the switch fabric or a channel from the system. Continue? [Y/N]

1.1.56  switch-fabric removal-signal-suppression

switch-fabric removal-signal-suppression命令用来抑制网板移出前向系统上报中断信号。

undo switch-fabric removal-signal-suppression命令用来恢复缺省情况。

【命令】

switch-fabric removal-signal-suppression

undo switch-fabric removal-signal-suppression

【缺省情况】

网板移出前会向系统上报中断信号。

【视图】

系统视图

【缺省用户角色】

network-admin

mdc-admin

【参数】

【使用指导】

为了避免因网板频繁误报中断信号而导致设备异常,可以配置网板移出信号抑制功能。

【举例】

#配置网板移出信号抑制功能。

<Sysname> system-view

[Sysname] switch-fabric removal-signal-suppression

1.1.57  switch-mode

switch-mode命令用于配置交换机业务板的工作模式

undo switch-mode命令用于恢复业务板的工作模式为缺省情况。

【命令】

独立运行模式:

switch-mode { normal | standard-ipv6 | bridging | routing | mix-bridging-routing | ipv6 } slot slot-number

undo switch-mode slot slot-number

IRF模式:

switch-mode { normal | standard-ipv6 | bridging | routing | mix-bridging-routing | ipv6 } chassis chassis-number slot slot-number

undo switch-mode chassis chassis-number slot slot-number

【缺省情况】

FB业务板的工作模式为normal,EC业务板的工作模式为mix-bridging-routing

【视图】

系统视图

【缺省用户角色】

network-admin

network-operator

mdc-admin

mdc-operator

【参数】

normal普通模式。

standard-ipv6:IPv6标准模式。

bridging:MAC扩展模式。

routing:路由扩展模式。

mix-bridging-routing:混合扩展模式。

ipv6:IPv6模式。

slot slot-number:业务板所在槽位号。

chassis chassis-number:表示IRF中设备的成员编号。(IRF模式)

【使用指导】

说明

·     业务板工作模式配置完毕后需保存配置并重启该业务板,所做配置才会生效。

·     业务板工作模式从routing/mix-bridging-routing/normal切换到bridging,或从brdging切换到routing/mix-bridging-routing/normal后,接口下的配置将丢失。请在重启业务板后,根据实际情况重新配置接口。

·     当交换机中存在多块业务板时,建议配置一致的工作模式。

·     对业务板进行初次模式切换或者模式切换后初次升级软件版本时,单板可能会因为系统优化自动重启1~2次,需要6~10分钟。

 

【举例】

# 配置设备2号槽位业务板的工作模式为IPv6标准模式。(独立运行模式)

<Sysname> system-view

[Sysname] switch-mode standard-ipv6 slot 2

# 配置2号成员设备上2号槽位业务板的工作模式为IPv6标准模式。(IRF模式)

<Sysname> system-view

[Sysname] switch-mode standard-ipv6 chassis 2 slot 2

【相关命令】

·     display switch-mode status

1.1.58  sysname

sysname命令用来设置设备的名称。

undo sysname用来恢复缺省情况。

【命令】

sysname sysname

undo sysname

【缺省情况】

设备的名称为H3C。

【视图】

系统视图

【缺省用户角色】

network-admin

mdc-admin

【参数】

sysname:设备名称,取值范围为1~64个字符的字符串。

【使用指导】

设备的名称对应于命令行接口的提示符,如设备的名称为Sysname,则用户视图的提示符为<Sysname>。

【举例】

# 设置设备的名称为R2000。

<Sysname> system-view

[Sysname] sysname R2000

[R2000]

1.1.59  system-working-mode

system-working-mode命令用来配置设备的工作模式。undo system-working-mode命令用来恢复缺省情况。

【命令】

system-working-mode { advance | standard }

undo system-working-mode

【缺省情况】

设备工作在标准模式。

【视图】

系统视图

【缺省用户角色】

network-admin

mdc-admin

【参数】

advance:将设备的工作模式设置为高级模式。

standard:将设备的工作模式设置为标准模式。

【使用指导】

不同模式下设备支持的特性不同,或者相同的特性支持的规格不同,请根据实际需要配置。例如:只有当设备工作在高级模式下才支持配置FCoE功能。

要使修改的工作模式生效,必须重启设备。

【举例】

# 将设备工作模式配置为高级模式。

<Sysname> system-view

[Sysname] system-working-mode advance

Do you want to change the system working mode? [Y/N]:y

The system working mode is changed, please save the configuration and reboot the system to make it effective.

1.1.60  temperature-limit

temperature-limit命令用于设置设备的温度告警门限。

undo temperature-limit命令用来恢复缺省情况。

【命令】

独立运行模式:

temperature-limit slot slot-number { hotspot | inflow } sensor-number lowlimit warninglimit [ alarmlimit ]

undo temperature-limit slot slot-number { hotspot | inflow } sensor-number

IRF模式:

temperature-limit chassis chassis-number slot slot-number { hotspot | inflow } sensor-number lowlimit warninglimit [ alarmlimit ]

undo temperature-limit chassis chassis-number slot slot-number { hotspot | inflow } sensor-number

【缺省情况】

请先使用undo temperature-limit命令恢复缺省情况后,再通过display environment命令查看单板的缺省温度告警门限。

【视图】

系统视图

【缺省用户角色】

network-admin

mdc-admin

【参数】

slot slot-number:配置指定单板上温度传感器的温度门限。slot-number表示单板所在的槽位号。

chassis chassis-number slot slot-number:设置指定单板或PEX设备的温度告警门限。chassis-number表示设备在IRF中的成员编号或PEX设备的虚拟框号,slot-number表示单板所在的槽位号。(IRF模式)

hotspot:配置热点传感器的温度门限。热点传感器一般置于发热量较大的芯片附近,监测芯片温度。

inflow:配置入风传感器的温度门限。入风传感器一般置于入风口附近,监测环境温度。

sensor-number:温度传感器的编号,取值为从1开始的正整数,每一个数字对应单板上的一个温度传感器。

lowlimit:低温告警门限,单位为摄氏度。

warninglimit:一般级(Warning)高温告警门限,单位为摄氏度。一般级高温告警门限必须大于低温告警门限。

alarmlimit:严重级(Alarm)高温告警门限,单位为摄氏度。严重级高温告警门限必须大于一般级高温告警门限。

【使用指导】

·     不同单板的温度传感器编号和温度告警门限取值范围不同,输入温度传感器编号或温度告警门限值时请通过<?>查看设备提示信息,以获取温度传感器编号或温度告警门限的取值范围。

·     如果温度低于低温告警门限,系统会生成日志信息和告警信息提示用户。

·     如果温度高于Warning高温门限,系统会生成日志信息和告警信息提示用户。

·     如果温度高于Alarm高温门限,系统一方面通过反复打印日志信息和告警信息提示用户,另一方面还会通过设备面板上的指示指示灯来告警。

·     如果业务板或网板温度高于关断级(Shutdown)高温告警门限,除生成日志和告警信息提示用户外,设备还会自动将该单板断电。

【举例】

# 配置0号单板上1号热点传感器,低温门限为-10摄氏度,Warning级高温门限为70摄氏度,Alarm级高温门限为95摄氏度。(独立运行模式)

<Sysname> system-view

[sysname] temperature-limit slot 0 hotspot 1 -10 70 95

# 配置1号成员设备0号单板上1号热点传感器,低温门限为-10摄氏度,Warning级高温门限为70摄氏度,Alarm级高温门限为95摄氏度。(IRF模式)

<Sysname> system-view

[sysname] temperature-limit chassis 1 slot 0 hotspot 1 -10 70 95

1.1.61  time at

time at命令用来配置在指定时刻执行Schedule。

undo time命令用来为Schedule取消执行时间配置。

【命令】

time at time date

undo time

【缺省情况】

没有为Schedule配置执行时间。

【视图】

Schedule视图

【缺省用户角色】

network-admin

mdc-admin

【参数】

time:Schedule的执行时间,格式为HH:MM(小时:分钟)。HH取值范围为0~23,MM取值范围为0~59。

date:Schedule执行的日期,格式为MM/DD/YYYY(月/日/年)或者YYYY/MM/DD(年/月/日)。

·     YYYY的取值范围为2000~2035;

·     MM的取值范围为1~12;

·     DD的取值范围与具体月份有关。

【使用指导】

配置的时间点必须晚于系统当前时间点,否则配置失败。

一个Schedule只能配置一个执行时间。因此,同一Schedule视图下,多次执行time attime oncetime repeating命令时,最新配置生效。

【举例】

# 配置2011年5月11日1点1分执行名称为saveconfig的Schedule。

<Sysname> system-view

[Sysname] scheduler schedule saveconfig

[Sysname-schedule-saveconfig] time at 1:1 2011/05/11

【相关命令】

·     scheduler schedule

1.1.62  time once

time once命令用来为Schedule配置执行时间。

undo time命令用来为Schedule取消执行时间配置。

【命令】

time once at time [ month-date month-day | week-day week-day&<1-7> ]

time once delay time

undo time

【缺省情况】

没有为Schedule配置执行时间。

【视图】

Schedule视图

【缺省用户角色】

network-admin

mdc-admin

【参数】

at time:Schedule的执行时间,格式为HH:MM(小时:分钟)。HH取值范围为0~23,MM取值范围为0~59。

month-date month-day:Schedule在一个月中的哪天被执行。month-day表示日期,取值范围为1~31。如果指定了一个本月不存在的日期,则实际生效的时间为下一个月的该日期,比如,二月没有30号,则实际生效的时间为三月的30号。

week-day week-day&<1-7>:Schedule在一周中的哪(些)天被执行。week-day&<1-7>表示一周中任一天或几天的组合,week-day取值为:MonTueWedThuFriSatSun,&<1-7>表示前面的参数最多可以输入7次。设置多天时,字符串之间用空格分开。

delay time:指定Schedule延迟执行的时间。格式为HH:MM(小时:分钟)或MM(分钟)。

·     使用HH:MM格式时,MM的取值范围为0~59,HH:MM最大长度为6个字符。

·     使用MM格式时,最大长度为6个字符。

【使用指导】

配置该命令后,Schedule在该设定时间点到达时执行,若当天/本月/本周该时间点已过去,则顺延到第二天/下月/下周。执行后下次再到达该时间点时Schedule不再执行。

一个Schedule只能配置一个执行时间。因此,同一Schedule视图下,多次执行time attime oncetime repeating命令时,最新配置生效。

【举例】

# 当天的15点执行名称为saveconfig的Schedule。

<Sysname> system-view

[Sysname] scheduler schedule saveconfig

[Sysname-schedule-saveconfig] time once at 15:00

# 最近到达的15号的15点执行名称为saveconfig的Schedule。

<Sysname> system-view

[Sysname] scheduler schedule saveconfig

[Sysname-schedule-saveconfig] time once at 15:00 month-date 15

# 最近一个周一和周五的12点整执行名称为saveconfig的Schedule。

<Sysname> system-view

[Sysname] scheduler schedule saveconfig

[Sysname-schedule-saveconfig] time once at 12:00 week-day mon fri

# 延迟10分钟执行名称为saveconfig的Schedule。

<Sysname> system-view

[Sysname] scheduler schedule saveconfig

[Sysname-schedule-saveconfig] time once delay 10

【相关命令】

·     scheduler schedule

1.1.63  time repeating

time repeating命令用来配置重复执行Schedule的时间。

undo time命令用来为Schedule取消执行时间配置。

【命令】

time repeating [ at time [ date ] ] interval interval-time

time repeating at time [ month-date [ month-day | last ] | week-day week-day&<1-7> ]

undo time

【缺省情况】

没有配置重复执行Schedule的时间。

【视图】

Schedule视图

【缺省用户角色】

network-admin

mdc-admin

【参数】

time:表示重复执行的时间,格式为HH:MM(小时:分钟)。HH取值范围为0~23,MM取值范围为0~59。不指定该参数时,表示从现在开始。

date:指定Schedule重复执行的开始日期,格式为MM/DD/YYYY(月/日/年)或者YYYY/MM/DD(年/月/日)。不指定该参数时,表示将来第一次到达time的时间点的日期。

·     YYYY的取值范围为2000~2035;

·     MM的取值范围为1~12;

·     DD的取值范围与具体月份有关。

interval interval-time:指定重复执行的时间间隔。格式为HH:MM(小时:分钟)或MM(分钟)。

·     使用HH:MM格式时,MM的取值范围为0~59,最大长度为6个字符。

·     使用MM格式时,取值的最小值为1,最大长度为6个字符。

month-date [ month-day | last ]:表示每月中的某一天。其中,month-day表示日期,取值范围为1~31。如果指定了一个本月不存在的日期,则实际生效的时间为下一个月的该日期,比如,二月没有30号,则实际生效的时间为三月的30号。last表示每月的最后一天。

week-day week-day&<1-7>:表示每周中的某(些)天。week-day&<1-7>表示一周中任一天或几天的组合,week-day取值为:MonTueWedThuFriSatSun,&<1-7>表示前面的参数最多可以输入7次。设置多天时,字符串之间用空格分开。

【使用指导】

time repeating [ at time [ date ] ] interval interval-time表示从指定时间开始,周期性执行Schedule。

time repeating at time [ month-date [ month-day | last ] | week-day week-day&<1-7> ]表示每月/每周的某(些)天重复执行Schedule。

一个Schedule只能配置一个执行时间。因此,同一Schedule视图下,多次执行time attime oncetime repeating命令时,最新配置生效。

【举例】

# 配置从早上八点开始,每隔1小时执行一次名称为saveconfig的Schedule。

<Sysname> system-view

[Sysname] scheduler schedule saveconfig

[Sysname-schedule-saveconfig] time repeating at 8:00 interval 60

# 配置从现在开始每天的12:00执行名称为saveconfig的Schedule。

<Sysname> system-view

[Sysname] scheduler schedule saveconfig

[Sysname-schedule-saveconfig] time repeating at 12:00

# 配置从现在开始每个月5号的上午8点执行名称为saveconfig的Schedule。

<Sysname> system-view

[Sysname] scheduler schedule saveconfig

[Sysname-schedule-saveconfig] time repeating at 8:00 month-date 5

# 配置从现在开始每个月的最后一天8点执行名称为saveconfig的Schedule。

<Sysname> system-view

[Sysname] scheduler schedule saveconfig

[Sysname-schedule-saveconfig] time repeating at 8:00 month-date last

# 配置从现在开始每个周五和周六的上午8点执行名称为saveconfig的Schedule。

<Sysname> system-view

[Sysname] scheduler schedule saveconfig

[Sysname-schedule-saveconfig] time repeating at 8:00 week-day fri sat

【相关命令】

·     scheduler schedule

1.1.64  user-role

user-role命令用来配置执行定时任务时使用的用户角色。

undo user-role命令用来删除执行定时任务时的用户角色。

【命令】

user-role role-name

undo user-role role-name

【缺省情况】

执行定时任务时使用的用户角色,为创建该Schedule的用户的用户角色。

【视图】

Schedule视图

【缺省用户角色】

network-admin

mdc-admin

【参数】

role-name:执行定时任务时使用的用户角色,为1~63个字符,区分大小写。可以是系统预定义的角色名称,包括network-admin、network-operator、mdc-admin、mdc-operator、level-0~level-15、security-audit,也可以是自定义的用户角色名称。

【使用指导】

本命令用来指定执行定时任务时的用户角色。通过配置和删除执行定时任务时的用户角色可以控制定时任务下的各个命令的执行。

用户在创建schedule后继承当前用户的权限。只有管理员角色才可以通过user-role命令给Schedule添加/删除角色,且配置的用户角色权限要小于当前用户的权限,否则配置不生效。

多次执行本命令可给Schedule配置多个用户角色,系统会使用这些用户角色权限的并集去执行Schedule。同一个Schedule最多可以配置64个用户角色。关于用户角色的详细描述请参见“基础配置指导”中的“RBAC”。

【举例】

# 配置执行定时任务test时使用的用户角色为rolename。

<sysname> system-view

[Sysname] scheduler schedule test

[Sysname-schedule-test] user-role rolename

[Sysname-schedule-test] display this                                             

#                                                                              

scheduler schedule test                                                         

 user-role network-admin                                                       

 user-role network-operator

 user-role rolename                                                            

#                                                                              

return

【相关命令】

·     command

·     scheduler schedule

不同款型规格的资料略有差异, 详细信息请向具体销售和400咨询。H3C保留在没有任何通知或提示的情况下对资料内容进行修改的权利!

新华三官网
联系我们