    Description

  • Description
  • Installation steps
  • Publish Description
  • Problems Solved
  • New Functions
  • Historical Versions
  • Description

    This software is used to upgrade the HDM version of the R4500 G6 server

  • Installation steps

  • Publish Description

    Supported products

    H3C UniServer R4700 G6

    H3C UniServer R4700LE G6

    H3C UniServer R4900 G6 Ultra

    H3C UniServer R4900 G6

    H3C UniServer R4900LE G6

    H3C UniServer R4500 G6

    H3C UniServer R4300 G6

    Restrictions and cautions

    Restrictions

    If no media images are mounted, the KVM window automatically closes when the HDM Web session times out.

    Each browser can establish only one session with HDM. If you attempt to establish two concurrent sessions from the same browser with different usernames, the first session will automatically end when the second session is established.

    For the new HDM firmware to take effect, restart HDM after update. The system will write the flash memory during the restart.

    Guidelines

    This version is available for all supported servers in this document.

    Make sure pop-ups are allowed on the browser.

    Version information

    Version number

    Image file names and the MD5 checksum:

    HDM2_2.13_signed.bin: e3beb5ae1614851ea319594ce1cc8429

     

     

    NOTE:

    You can access the HDM Web interface of the server to identify the HDM version in the Device information section of the Dashboard page.

     

    Supported languages

    HDM supports the following languages:

    Chinese.

    English.

    Supported browsers

    As a best practice, use one of the following browsers:

    Edge 108 or higher.

    Firefox 90.0.0 or higher.

    Chrome 80 or higher.

    Safari 14 or higher.

    Supported hardware platforms

    H3C UniServer R4700 G6

    H3C UniServer R4700LE G6

    H3C UniServer R4900 G6 Ultra

    H3C UniServer R4900 G6

    H3C UniServer R4900LE G6

    H3C UniServer R4500 G6

    H3C UniServer R4300 G6

    Hardware and software compatibility matrix

    IMPORTANT:

    The following version combinations are required for specific functions but are not mandatory.

     

    Table 1 Hardware and software compatibility matrix (for the R3950 G6)

    Item

    Specifications

    Product family

    H3C UniServer R3950 G6

    BIOS

    Version 6.30.26 or later

    CPLD

    CPLD1: Version 001 or later

    CPLD2: Version 001 or later

    iMC

    iom E0707

    UniSystem

    Version 2.60 or later

    FIST SMS

    Version 1.60 or later

    iFIST

    Version 1.60 or later

     

    Table 2 Hardware and software compatibility matrix (for the R5500 G6 Intel)

    Item

    Specifications

    Product family

    H3C UniServer R5500 G6 Intel

    BIOS

    Version 6.10.40 or later

    CPLD

    Version 003 or later

    SWITCH CPLD

    Version 003 or later

    iMC

    N/A

    UniSystem

    Version 2.60 or later

    FIST SMS

    Version 1.60 or later

    iFIST

    Version 1.60 or later

     

    Table 3 Hardware and software compatibility matrix (for the R5300 G6 Intel)

    Item

    Specifications

    Product family

    H3C UniServer R5300 G6 Intel

    BIOS

    Version 6.10.40 or later

    CPLD

    Version 006 or later

    iMC

    N/A

    UniSystem

    Version 2.60 or later

    FIST SMS

    Version 1.60 or later

    iFIST

    Version 1.60 or later

     

    Table 4 Hardware and software compatibility matrix (for the R5350 G6)

    Item

    Specifications

    Product family

    H3C UniServer R5350 G6

    BIOS

    Version 6.30.31 or later

    CPLD

    Version 007 or later

    iMC

    N/A

    UniSystem

    Version 2.60 or later

    FIST SMS

    Version 1.60 or later

    iFIST

    Version 1.60 or later

     

    Table 5 Hardware and software compatibility matrix (for the R4500 G6)

    Item

    Specifications

    Product family

    H3C UniServer R4500 G6

    BIOS

    Version 6.10.41 or later

    CPLD

    Version 001 or later

    iMC

    N/A

    UniSystem

    Version 2.60 or later

    FIST SMS

    Version 1.60 or later

    iFIST

    Version 1.60 or later

     

    Table 6 Hardware and software compatibility matrix (for the R4900 G6 Ultra, R4900/R4900LE G6, R4700/R4700LE G6)

    Item

    Specifications

    Product family

    H3C UniServer R4900 G6 Ultra, R4900/R4900LE G6, R4700/R4700LE G6

    BIOS

    Version 6.10.42 or later

    CPLD

    Version 005 or later

    iMC

    iom E0709

    UniSystem

    Version 2.60 or later

    FIST SMS

    Version 1.60 or later

    iFIST

    Version 1.60 or later

     

    Table 7 Hardware and software compatibility matrix (for the R4300 G6)

    Item

    Specifications

    Product family

    H3C UniServer R4300 G6

    BIOS

    Version 6.10.38 or later

    CPLD

    Version 001 or later

    iMC

    iom E0711P01

    UniSystem

    Version 2.60 or later

    FIST SMS

    Version 1.60 or later

    iFIST

    Version 1.60 or later

     

    Upgrade restrictions and guidelines

    Make sure the software versions are compatible with each other. For more information, see "Hardware and software compatibility matrix."

    As a best practice, back up the configuration before you update the firmware. For more information, see "(Optional) Backing up the current configuration."

    To update both HDM and the BIOS, update HDM first.

    Make sure the server operates correctly or is powered off during BIOS or HDM update.

    During the update, make sure the network connection is available and do not refresh the Webpage.

    To avoid HDM or operating system errors, do not power on or power off the server during the firmware update.

    After the firmware is updated, delete the browsing history before you re-log in to HDM. For more information, see "Clearing the browser cache."

    Upgrade recommendation

    This version is optional for update. 

  • Problems Solved

    Resolved problems in HDM2-2.13

    202409250265

    Symptom: IPMI commands might fail to be issued.

    Condition: This symptom might occur if stress tests with large data output are perform in the OS in an in-band manner and the SOL feature are repeatedly enabled and disabled by using IPMI commands.

    202409191716

    Symptom: The server installed with multiple MCTP PCIe modules mistakenly reports a PCIe state error.

    Condition: This symptom might occur if the server is installed with multiple MCTP PCIe modules.

    202409241534

    Symptom: IPMI commands might fail to be issued after a BMC reboot.

    Condition: This symptom might occur if BMC reboots.

    202409140953

    Symptom: When the R4950 G6 server is installed with network adapters and IB cables from Mellanox, the fan speed becomes abnormally high.

    Condition: This symptom might occur if the R4950 G6 server is installed with network adapters and IB cables from Mellanox.

  • New Functions

  • Version:2.14(2024/12/2)

    Upgrade recommendations

    optional for update.

    Problems Solved

    Resolved problems in HDM2-2.14

    202411010977

    Symptom: HDM might restart and generate log messages about BMC warm reset.

    Condition: This symptom might occur if you run the IPMI script in the OS in an in-band manner and upgrade HDM in an out-of-band manner at the same time.

    New Functions

    Version:2.13(2024/11/4)

    Upgrade recommendations

    optional for update.

    Problems Solved

    Resolved problems in HDM2-2.13

    202409250265

    Symptom: IPMI commands might fail to be issued.

    Condition: This symptom might occur if stress tests with large data output are perform in the OS in an in-band manner and the SOL feature are repeatedly enabled and disabled by using IPMI commands.

    202409191716

    Symptom: The server installed with multiple MCTP PCIe modules mistakenly reports a PCIe state error.

    Condition: This symptom might occur if the server is installed with multiple MCTP PCIe modules.

    202409241534

    Symptom: IPMI commands might fail to be issued after a BMC reboot.

    Condition: This symptom might occur if BMC reboots.

    202409140953

    Symptom: When the R4950 G6 server is installed with network adapters and IB cables from Mellanox, the fan speed becomes abnormally high.

    Condition: This symptom might occur if the R4950 G6 server is installed with network adapters and IB cables from Mellanox.

    New Functions

    Version:2.12(2024/10/18)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in HDM2-2.12

    202409110225

    Symptom: When you use IPMItool to issue the sdr elist command, the output has repeated items.

    Condition: This symptom might occur if you use IPMItool to issue the sdr elist command

    202408151920

    Symptom: With the VNC service enabled, when you use the NoVNC client to create a VNC session, a connection failure might occur.

    Condition: This symptom might occur if you use the NoVNC client to create a VNC session with the VNC service enabled.

    New Functions

    Version:2.11(2024/9/24)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in HDM2-2.11

    N/A

    New Functions

    Version:2.10.02(2024/9/24)

    Upgrade recommendations

    Recommended Upgrade

    Problems Solved

    Resolved problems in HDM2-2.10.02